USER MANUAL 

– MINIVAC 

 

Page 

4

 of 

14

 

INMANUUIN198 Rev.2019.11.01 / ENG 

  Prevent  the  power  supply  cable  from  being  walked  over  or  placed  under  any  piece  of 

furniture. 

  Do not use the device during thunderstorms. 

  After the use of the device, turn it off and disconnect the power cable. 

  In  order  to  avoid  Electrical  shocks  this  system  must  be  connected  to  a  power  grid  with 

proper ground connection (no exceptions). 

  The  device  is  provided  with  a  connectable  power  cable  that  assures  proper  electrical 

isolation on the grid.  

  In  the  case  of  electromagnetic  interference  between  medical  device  and  other  electrical 

device, we recommend to increase the distance between the systems in order to minimize 
the interference effects. 

  Do  not  open  the  device.  The  diagnose,  service  and  repairs  must  be  performed  by 

ECLERIS,  or  a  company  authorized  by  ECLERIS.    ECLERIS  will  not  be  liable  for  the 
damage caused by repairs, or service performed by unauthorized personnel. 

  In  case  of  any  problem,  the  system  must  be  laid  on  a  plane  surface  and  power  cable 

disconnected. 

  The device must be used only by personnel informed of all this warnings. 

  Any  use  outside  of  the  manufacturer  specific  intent  use,  will  exclude  ECLERIS  of  all 

liability. 

  This user manual must be with the device for permanent review.  If the system  is sold or 

donated, the user manual must be delivered with the device. 

If as a consequence of: 

  Inadequate use of the equipment 

  No use of this manual 

  Poor care and maintenance of the equipment 

  Repair and manipulation by unauthorized personnel 

…any material or personal damages were caused to third parties, ECLERIS, the manufacturer or 
the supplier of the equipment shall not assume any responsibility for such damages. 

Do  not  dispose  of  the  device,  or  any  of  the accessories with  the  domestic  waste. 
Research  the  local  rules  and  laws  for  proper  disposal.  It  is  the  user  responsibility  to 
deliver  the  system  to  the  proper  location  for  disposal  or  recycle  of  electrical  and 
electronic devices or contact the manufacturer or authorized representative to proceed 
on the elimination of the system on a safe and ecological way. 

2.2 CONTRAINDICATIONS 

 

Pregnancy. 

 

Botulin toxin: do not treat until 30 days have passed and never in the application area. 

 

Surgical intervention, not until 40 days have passed. 

 

Herpes zoster. 

 

Skins that were recently treated with other types of exfoliation. 

 

Highly sensitive skins. 

 

Extremely fine skins. 

 

Active acne. 

 

Uncontrolled diabetes. 

 

Eczemas. 

 

Dermatitis. 

 

Skin cancer. 

Содержание MINIVAC

Страница 1: ...ny electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it representing any responsibility to ECLERIS ECLERIS S R L...

Страница 2: ...UP 7 4 1 INSTALLATION 7 4 2 REVISION 7 4 3 VACUUM SYSTEM VERIFICATION 8 5 OPERATION 8 5 1 VACUUM INTENSITY 8 5 2 DIAMOND TIP 9 5 3 PRE TREATMENT RECOMMENDATIONS 9 5 4 TREATMENT 9 5 5 POST TREATMENT RE...

Страница 3: ...ontact your local distributor or the nearest ECLERIS office ECLERIS shall not be liable for the damages that may occur if the equipment is not used according to these instructions and following the cr...

Страница 4: ...e manufacturer specific intent use will exclude ECLERIS of all liability This user manual must be with the device for permanent review If the system is sold or donated the user manual must be delivere...

Страница 5: ...in disorders and those caused by aging Due to microdermabrasion the skin becomes more receptive and the absorption of applied products increases without causing any pH alteration The Ecleris Minivac p...

Страница 6: ...proceed with the installation 1 Main unit 1 AC interlock cable 1 Quick assembly coupling hose 1 Diamond Tip Kit 1 User s manual Contact your supplier for customized Diamond Tip kits availability 3 4...

Страница 7: ...knurled hand piece 1 7 The 45 angular 3 adapter can be placed in the free end of the vacuum regulator depending on the use perpendicular to the tissue or at 45 Place a 50 75 100 150 or 200 microns Dia...

Страница 8: ...lating valve clockwise all the way 2 Place the applicator on the back of your hand As soon as it gets in contact with your skin suction will begin The maximum vacuum level should be approximately 60cm...

Страница 9: ...inest tip and with low vacuum pressure Once the three parameters have been decided regulate vacuum intensity Vacuum pressure controls the skin pressure on the diamond tips 50 and 75 micron tips and a...

Страница 10: ...aning the Ecleris Minivac disconnect the power supply cable from the electrical network 6 1 1 EXTERNAL SURFACES Clean the external surface of the equipment using a piece of cotton or cloth moistened w...

Страница 11: ...s they will produce air leakage lowering the vacuum level Never use the Ecleris Minivac without the micro porous filter and the collecting receptacle The Ecleris Minivac was not designed for liquid ab...

Страница 12: ...FILTER Micro porous Micro porous FUSES T5AL250V T2 5AL250V T4AL250V T2AL250V CONSUMO CONSUMPTION 275 VA 90 VA DIMENSIONS 35x22x16 cm 35x22x16 cm WEIGHT 4 Kg 5 5 Kg OPERATING CONDITIONS 10 40 C 35 75 r...

Страница 13: ...again The Ecleris Minivac starts but does not produce vacuum The vacuum regulator is completely open Close the regulator by turning it clockwise The suction piping is throttled Check that the hose is...

Страница 14: ...ame Owner s address Person to contact and a telephone number Product serial number Problem description The shipment should be done in the original packaging to avoid damage to the equipment during the...

Отзывы: