background image

 

3

INTRODUCTION 

The stereo processor module UCM 20 - Universal Crossover Module is a card that has been specially designed to 
fit into ECLERs APA and DPA Series SPM Technology power amplifiers.  
The UCM 20 card has been conceived for its use in bi-amplified applications. A 24dB/oct Linkwitz-Riley crossover 
filter confers the system great precision and smooth operation, minimizing cancellations and other phase  related 
problems other configurations show. Cut off frequency can be pre-set from 100 to 200Hz. The UCM 20 can operate 
as a high pass and a low pass filter, both for the amplifier into which it is installed, as for an external amplifier. The 
action of the filter can be bypassed, so that the selected amplifier operates in full-range mode. These features make 
an UCM 20 fitted amplifier an extremely versatile unit. 
 

CONNECTION INSTRUCTIONS 

The Cut off frequency and the input sensibility of the UCM 20 are factory preset at 100Hz and 0dBV respectively. 
These settings can be easily modified (See paragraphs “SELECTING CUT OFF FREQUENCY” and “INPUT 
SENSIBILITY”). No other adjustments are necessary before installing the card into the amplifier.  
Keep in mind that the APA and DPA Series power amplifiers feature an efficient ANTICLIP system. Detailed 
information about this protection system can be found in the instruction manual that came with your power 
amplifier. 
The attenuation potentiometers of the power amplifier should be left “open”, i.e. no attenuation should be applied. 
However, these controls could be used to attenuate a problematic frequency range in acoustically poor rooms as a 
first step for finer equalization. 
IMPORTANT: In order to avoid damage to the loudspeakers, equipment should be turned on in sequence following 
the same path as the audio signal flow. Last you should turn on the bass amplifier. Devices should be turned off 
following the inverse sequence. 
 

SELECTING CUT OFF FREQUENCY 

Cut off frequency is selected using two four position switches found on the card. Separate switches are provided for 
the L and R channels (8-9). The available cut off frequency steps are (from left to right): 100, 125, 150 and 200 Hz, 
as depicted on the cards chassis. The blank space (10) on the front panel marked “FREQ-Hz” can be used to place 
a provided sticker, onto which the selected cut off frequency can be written. 
A set of FILER/FLAT switches (1-3) placed on the external panel of the card are used to bypass the action of the 
filters, so the power amplifiers can be used both for bi-amplified applications and as full-range units. The HP/LP 
switches (2-4) let you decide whether the amplifiers should operate on the low frequencies (LP) or high frequencies 
(HP). This can be set independently both for the host amplifier with the UCM 20 card and the amplifier connected to 
the unbalanced “EXT. AMPLIFIER OUT” (5-6) 
 

INPUT SENSIBILITY 

Input sensibility can be adjusted from 0dBV to +6dBV with a set of jumpers found on the card and following the 
instructions printed on the card chassis. This setting affects both the host and the external amplifier and is always 
active, regardless of the position of the “FILTER/FLAT” switches (1-3). 
 

INSTALLATION 

1. Disconnect the amplifier from mains supply 
2. Unscrew the top cover and the blank panel on the rear of the unit 
3. Remove the two jumpers of the connector found on the input stage of the amplifier. Save the jumpers and the 

blank panel. You will need them in the future if you decide to use the power amplifier without the filter again. 

4. Insert the filter into the slot of the rear panel and connect the filter cable (see diagram)  
5. Screw the Filter and the top cover to the chassis. 

CAUTION: The installation of the filter should be performed by a qualified technician. 

Содержание UCM 20

Страница 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG UCM 20 ...

Страница 2: ......

Страница 3: ...s the audio signal flow Last you should turn on the bass amplifier Devices should be turned off following the inverse sequence SELECTING CUT OFF FREQUENCY Cut off frequency is selected using two four position switches found on the card Separate switches are provided for the L and R channels 8 9 The available cut off frequency steps are from left to right 100 125 150 and 200 Hz as depicted on the c...

Страница 4: ...s graves El apagado será en el orden inverso SELECCIÓN FRECUENCIA DE CORTE Ésta se realiza mediante los conmutadores de 4 posiciones situados en la tarjeta existiendo uno para cada canal L y R 8 y 9 Las frecuencias disponibles en cada salto de izquierda a derecha son 100 125 150 y 200 Hz tal y como aparece en el diagrama dibujado en el propio chasis de la tarjeta Un espacio 10 en el frontal de la ...

Страница 5: ...insi allumé en dernier La mise hors service des appareils se fera donc en respectant la séquence inverse SELECTION DE LA FREQUENCE DE COUPURE Pour effectuer cette sélection utiliser les mini commutateurs 4 positions situés sur la carte un commutateur pour la voie gauche L et un pour la voie droite R 8 et 9 Les fréquences disponibles de gauche à droite respectent les pas 100 125 150 et 200 Hz comme...

Страница 6: ... inverse Reihenfolge beachten EINSTELLEN DER TRENNFREQUENZ Die Trennfrequenz wird durch die 4 stufigen Schalter die Sie auf der Karte finden eingestellt wobei separate Schalter für den linken L und rechten R Kanal vorhanden sind 8 9 Die verfügbaren Trennfrequenzen sind 100 125 150 und 200 Hz von links nach rechts aufgelistet Diese Werte sind in einem Diagramm auf der Metallplatine der Karte gedruc...

Страница 7: ...V 46kΩ Outputs Level Minimum Load UNBAL 0dBV 2kΩ THD N 0 01 Signal Noise Ratio 100Db Crosstalk 100dB Linkwitz Riley Filters 24dB oct Slope in all the cases Cut frequency at 6dB 100 Hz Cut frequency at 6dB 125 Hz Cut frequency at 6dB 150 Hz Cut frequency at 6dB 200 Hz Dimensions Panel 30x113mm Depth 80mm Weight 125g Internally selectable ...

Страница 8: ...LOW FILTER FLAT SENSIBILITY ADJUST 0dB 6dB FREQUENCY SELECTOR 100 125 150 200 Hz FREQUENCY SELECTOR LINKWITZ RILEY CROSSOVER CIRCUIT HP HIGH LP LOW FLAT FILTER FLAT FILTER HIGH LOW LOW HIGH FILTER FLAT SENSIBILITY ADJUST 0dB 6dB L EXT AMPLIFIER OUTPUT R EXT AMPLIFIER OUTPUT INPUT L INT AMPLIFIER OUTPUT L INPUT R R INT AMPLIFIER OUTPUT ...

Страница 9: ...IER 1 JACK TIP HOT RING COLD XLR3 PIN2 HOT PIN3 COLD INT AMPLIFIER OUTPUT CH1 2 2 BRIDGED STK OUTPUT BRIDGE INPUT 1 1 CH2 OUTPUT 1 1 CH1 STEREO CHANNEL 2 INPUT STK OUTPUT INPUT CHANNEL 1 BRIDGE 200 Hz 100 Hz 0dB JUMPERS CONFIGURATION 6dB L R INPUT LEVEL ON OFF FILTERS 125 Hz 150 Hz APA1400 1000 600 ORIGINAL FACTORY CONFIGURATION FILTERS INPUT LEVEL 100Hz 0dB EXT AMPLIFIER OUTPUT TO CONNECT UCM 20 ...

Страница 10: ...LEVEL 100Hz 0dB TO CONNECT UCM 20 2 x JUMPERS MUST BE REMOVED TO CONNECT UCM 20 3x N C 2x N C UCM 20 AMPLIFIER UCM 20 2x N C 3x N C AMPLIFIER AMPLIFIER 1 AMPLIFIER 2 OUTPUT INT AMPLIFIER INPUT INT AMPLIFIER FREQ FLAT FILTER LP HP L UCM 20 EXT AMPLIFIER OUTPUT FLAT FILTER Hz R LP HP OUTPUT EXT AMPLIFIER ORIGINAL FACTORY 110 120V 220 240V DPA SERIES DPA1000 DPA1400 ...

Страница 11: ...Diagramme de fonctions Funktionsübersicht 1 Connexion déconnexion du filtre à l amplificateur 1 Einschalten Ausschalten des Filters der Host interne Endstufe 2 Sélecteur filtre passe bas ou passe haut 2 Hochpass Tiefpass Einstellung für die Host amplificateur interne Endstufe 3 Connexion déconnexion du filtre à l amplificateur 3 Einschalten Ausschalten des Filters der externen externe Endstufe 4 S...

Страница 12: ...ECLER Laboratorio de electro acústica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com E mail info ecler es 50 0073 01 01 ...

Отзывы:

Похожие инструкции для UCM 20