Ecler PhiloS Series Скачать руководство пользователя страница 5

5

5. CONNECTIONS 

 

The connection cables which connect the amplifiers output and the speaker should be 

of good quality, have sufficient conductor area and be as short as possible. The latter fact is 
specially important when the distance is long and the load impedance low (4-8 

). A cross-

section of at least 2.5mm

2

 is recommended for distances up to 10m; 4 or 6mm

2

 for longer 

distances. Following formula gives the required section, assuming 4% losses: 

 

 

 

 

 

             Length in m 

Cross section in mm

2

  



 

 

 

 

 

                 Loudspeaker Impedance in 

 

 

 

Always respect polarity. All connections are Speak-on type. The pin-out is indicated in 

the diagram. 

 

 

6. RECOMMENDED AMPLIFIER 

 

Following table shows the output power of the amplifier adequate to each acoustic 

system: 

 

PHILOS 10 between 200 and 400W 

PHILOS 12 between 250 and 500W 

PHILOS 15 between 300 and 600W 

 

 

7. PRE-AMPLIFYING MIXERS 

 

 

Avoid excessive gain adjustments in the equalizer or tone control sections. 

 
 

8. PLACEMENT AND MOUNTING 

 

Consider following general rules: 

Place the acoustic enclosures on solid and firm surfaces. No  obstacles should stand 

between the enclosures and the audience. The high frequencies are very directive compared to 

the low frequencies, so that any obstacle will impair their response. In case large audiences 

must be addressed, a better long distance sound propagation will be achieved if the enclosures 

are flown high enough. 

Two stands are provided with each PHILOS cabinet in order to be installed in one of 

the sides allowing the speaker cabinets to be used as stage monitors (see drawing) 

 
 

9. SUSPENDING THE UNIT 

 

 

The PHILOS series acoustic enclosures may be flown either using the optional SR 12 

accessory or by using its 10 rigging points. 

 

These rigging points consist of four embedded nuts on the back and six nuts on the 

top and bottom of the unit. 

When using SR12 fixings, an additional safety cable must be attached. 

The units must never be flown from their transportation handles. 

Содержание PhiloS Series

Страница 1: ...INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI SERIES...

Страница 2: ......

Страница 3: ...PLIFIER 05 7 PRE AMPLIFYING MIXERS 05 8 PLACEMENT AND MOUNTING 05 9 SUSPENDING THE UNIT 05 10 TECHNICAL CHARACTERISTICS 13 11 DIAGRAMS 14 All numbers subject to variation due to production tolerances...

Страница 4: ...application 3 INTRODUCTION These acoustic enclosures have been designed to offer a wide range of applications Starting with conference rooms where superior intelligibility is required or outdoor insta...

Страница 5: ...justments in the equalizer or tone control sections 8 PLACEMENT AND MOUNTING Consider following general rules Place the acoustic enclosures on solid and firm surfaces No obstacles should stand between...

Страница 6: ...DO 08 7 MEZCLADORES PRE AMPLIFICADORES 08 8 UBICACI N Y MONTAJE 08 9 SUSPENSI N 08 10 CARACTER STICAS T CNICAS 13 11 DIAGRAMAS 14 Todos los datos est n sujetos a variaci n debida a tolerancias de prod...

Страница 7: ...ce los accesorios adecuados a cada cometido 3 INTRODUCCI N Dise adas para cubrir una amplia variedad de aplicaciones desde salas de conferencia donde se requiere una gran inteligibilidad a aplicacione...

Страница 8: ...RES Evite los ajustes excesivos de ganancia en ecualizadores y controles de tono 8 UBICACI N Y MONTAJE Como reglas generales se observar n las siguientes Colocar las cajas ac sticas en superficies s l...

Страница 9: ...L EMPLACEMENT ET INSTALLATION 12 9 FIXATION EN HAUTEUR 12 10 CARACTERISTIQUES TECHNIQUES 13 11 SCHEMAS 14 Le contenu de ce manuel peut tre amen changer du fait de tol rances de production La soci t E...

Страница 10: ...u de poser sur ce dernier des r cipients contenant des liquides de quelque nature qu ils soient Eviter d installer cet quipement proximit d une source de chaleur d un foyer ou d un po le N utiliser qu...

Страница 11: ...nte et le plus court possible Ces conditions rev tent une importance toute particuli re lorsque les distances couvrir sont cons quentes des basses imp dances 4 8 Lorsque la distance de c blage ne d pa...

Страница 12: ...la distance est obtenue au contraire en installant les enceintes en hauteur Les enceintes PHILOS sont fournis avec deux pieds qui une fois fix s sur le lat ral de l enceinte permettrant l utilisation...

Страница 13: ...range speaker Driver 12 x1 Bass 1x44mm Treble Frequency response 3dB 50Hz 18KHz Sensitivity dB IM IW 97dB Impedance 8 ohms Power rating RMS 250W Maximum SPL dB M 120dB Dispersion HxV 90 x 60 Connector...

Страница 14: ...14 11 DIAGRAMS 11 DIAGRAMAS 11 SCHEMAS...

Страница 15: ...15 CH I CH II OUTPUT 1 1 2 2 LIVE GND N C N C 2 1 2 1...

Страница 16: ...ECLER Laboratorio de electro ac stica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com E mail info ecler es 50 0074 01 03...

Отзывы: