10
Note:
in this mode, if (by mistake) the primary and secondary ports connect to the
same Ethernet network, Dante Controller will no longer have access to the
network configuration control and routing Dante™ of the
MIMO7272DN ports.
This control is recovered when one of them is disconnected from the same
network as the other.
Note:
Dante™ redundancy requires that the pr
imary and secondary ports of all
Dante™ devices connect using the same network connection speed. For example,
if the primary port connects to a network with a 1 Gbps link, the secondary port
must
also
connect
at
1
Gbps.
•
Switched mode:
in this mode, only a single network connection is actually enabled
(and therefore only one IP address exists), with the primary and secondary ports
behaving as ports of a network switch integrated within MIMO7272DN, to which
devices forming part of the system's Dante™ network
, or Ethernet switches
forming part of that network's infrastructure, can be directly connected.
Note:
in this mode both ports
primary and secondary, should never be
connected simultaneously to network switches
, as this would create a loop that
would cau
se network conflicts and disruption of the digital audio Dante™ traffic.