![Ecler GPA2-400ES Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/ecler/gpa2-400es/gpa2-400es_user-manual_533346012.webp)
12
10.
TECHNICAL CHARACTERISTICS
POWER 20-20kHz 1% THD:
1 Channel @ 4
390 WRMS
1 Channel @ 8
280 WRMS
All Channels @ 4
350 WRMS
1 Bridged Channel @ 8
700WRMS
Frequency response (-1dB, -3dB)
20Hz - 40kHz
Filter (High-Pass) 3rd order Butterworth
50Hz
THD+Noise @ 1kHz Full Pwr.
<0.05%
Intermodulation distortion 50Hz & 7kHz, 4:1
<0.06%
TIM 100
<0.04%
S+N/N 20Hz - 20kHz @ 1W/4
>85dB
CMRR
>55dB
Damping factor 1kHz @ 8
>360
Channel crosstalk @ 1kHz
>55dB
Input Sensitivity / Impedance
0dBV/>20k
Anticlip
@ 2dBV input
<5% THD
Mains Voltage
See characteristics in the back of
the unit.
Power consumption (pink noise, 1/8 power @ 4ohm)
143W / 204VA
Power consumption (pink noise, 1/3 power @ 4ohm)
334W
Power consumption (Idle)
25W
Power consumption (STBY)
17W
Efficiency (typical)
85%
STBY time
90s
Dimensions (Handle excluded)
482.6x88x373mm
Weight
10.4kg