background image

 

2

1. IMPORTANT REMARK 

We thank you for trusting in us and choosing our DLA600B adaption unit. In order to get the optimum 

operation and efficiency from this unit, it is VERY IMPORTANT - before you plug anything - to read this manual 
very carefully and bear in mind all considerations specified within it.  

We strongly recommend that its maintenance be carried out by our Authorised Technical services. 
Do not expose the unit to rain or water splashes, and do not place liquid containers or incandescent 

objects like candles on top of the unit. Do not obstruct the ventilation shafts with any kind of material. 
There are no user serviceable parts inside the unit. 

 
 
INTRODUCTION 
 

The use of a 70V / 100V loudspeaker distribution system responds to the necessity of a flexible system 

that firstly allows the simultaneous use of different types of loudspeakers with different impedances, power 
handlings, etc. and secondly minimises the power loss caused by the conductor resistance in long cable runs. 

Basically, the system uses transformers to adapt each loudspeaker to the 70V / 100V line. These line 

voltages are achieved either with high output power amplifiers (e.g. 1250 @ 8

) or with smaller power 

amplifiers followed by an output transformer. 

In order to use conventional medium-sized power amplifiers in 70V /100V lines (e.g. hotels, factories, 

train stations, bus terminals, stores, supermarkets, parks, streets… ) it is required to place an intermediate unit 
between the amplifier’s output and the loudspeaker line. The DLA600B fulfils this task and offers exceptional 
flexibility thanks to its two independent channels for 100V and 70V outputs. 

The DLA600B intermediate unit complements ECLERs power amplifiers MPA4-80, MPA6-80, MPA4-

150, MPA4-400 and APA600, although it’s perfectly suited for other amplifiers with similar characteristics. 
 
 
INSTALLATION TIPS 

As in many other systems, it’s highly recommended not to reduce the total load impedance below the 

minimum admissible impedance. The usual procedure for calculating the maximum number of loudspeakers 
that a given line can bear, is to sum the power handling of all loudspeakers and check that this sum is not bigger 
than the maximum output power of the amplifier. 

For the previous statement to be true, and to ensure a trouble-free operation of the power amplifier, 

loudspeakers should be of the highest affordable quality and be installed correctly. 

To guarantee an optimum performance of the DLA600B, the output power of the amplifier should be as 

similar as possible to the selected input power on the DLA600B. 

If the output power of the amplifier does not match any of the 3 options on the DLA600B, set in to the 

higher rated input selection. For example, if you have a 200W amplifier, you should choose the 300W input 
setting on the DLA600B. 

Keep in mind that if these power figures do not match, the output voltage of the DLA600B will not be 

exactly 100V or 70V. 

If you use a higher output power on a lower rated DLA600B configuration, you run the risk of saturating 

the transformer and poor system performance. 

Always refer to the indications printed on the panel when connecting the inputs and outputs to the 

DLA600B. These indications are reproduced at the end of this manual together with two installation examples. 

The DLA600B features lateral rack ears that allow, thanks to its standard 19’’ width (482.6 mm) and 1 

unit height (44mm), installation in normalized rack furniture. 
 
 
CLEANING 
 

The front panel should not be cleaned with dissolvent or abrasive substances because silk-printing could 

be damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth. Be 
careful that water never gets into the unit through the holes of the unit. 
 
 
 
 
 
 
 
 
 

All numbers subject to variation due to production tolerances. ECLER S.A. reserves the right to make changes or improvements in 
manufacturing or design which may affect specifications.

 

Содержание DLA600B

Страница 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG DLA600B ...

Страница 2: ...r systems it s highly recommended not to reduce the total load impedance below the minimum admissible impedance The usual procedure for calculating the maximum number of loudspeakers that a given line can bear is to sum the power handling of all loudspeakers and check that this sum is not bigger than the maximum output power of the amplifier For the previous statement to be true and to ensure a tr...

Страница 3: ...ísticas RECOMENDACIONES DE INSTALACIÓN Es importante como en cualquier otro sistema no bajar la impedancia de la carga por debajo de la impedancia mínima admisible La manera usual de calcular el número máximo de altavoces que permite cada línea es sumar las potencias de cada altavoz y que la suma no supere la potencia máxima del amplificador Para que se cumpla el principio anterior y el amplificad...

Страница 4: ...r de puissance présentant les mêmes caractéristiques RECOMMENDATIONS RELATIVES A L INSTALLATION Il est important comme pour tout autre système de ne pas réduire l impédance de la charge en deçà du seuil minimal admissible Pour calculer le nombre maximum de haut parleurs autorisés sur chaque ligne on additionne généralement les puissances de chaque haut parleur et l on s assure que la somme obtenue...

Страница 5: ...NSTALLATION Wie in vielen anderen Systemen ist es sehr wichtig das die installierte Gesamtimpedanz einen höheren Wert als die von der Endstufe akzeptierte Mindest Lastimpedanz hat Die gewöhnliche Methode um die maximale Anzahl anschließbarer Lautsprecher zu berechnen besteht darin die Nennleistung aller Lautsprecher zu addieren und sicherzustellen daß diese Summe niedriger ist als die maximale Aus...

Страница 6: ...OL 1 2 4 B GAIN 0 20 SP dB CLIP 20 6 7 9 10 8 5 3 VOL 1 2 5 MONO OUT A 0 15 3 VOL 1 A B GAIN 0 CLIP 20 SP dB 20 8 6 7 9 10 5 4 0 2 6 BASS A B 0 15 L dB 10 6 10 5 4 0 7 9 8 STEREO BASS dB 15 MID 0 0 TREB 10 dB 15 R 6 15 dB 15 0 15 6 3 4 VOL 0 1 2 6 7 9 10 8 5 0 0 MID TREB 15 10 L 6 15 0 dB 15 10 15 R dB 0 OUT B 5 3 4 VOL 0 1 2 POWER 6 10 MONITOR 2 B 6 15 0 1 VOL 6 7 9 8 A 5 3 4 8 9 ON PHONES 7 OFF ...

Страница 7: ...0 15 BASS 15 0 20 GAIN 0 20 OUTPUT 2 OUTPUT 1 PHANTOM VU POWER OFF ON 6 0 10 20 40 L R L R AUX IN 3 TIME 0 3 3 s EFF 0 30dB MIC LINE A LINE B PH LINE B LINE A MIC LINE LINE MIC MIC LINE AUX 10 9 8 7 6 5 4 3 2 1 0 VOLUME SIGNAL PEAK 2 1 3 4 5 VOLUME MID 0 BASS 15 15 15 15 0 TREB 20 15 GAIN 20 15 0 0 VOLUME MID 0 BASS 15 15 15 15 0 TREB 20 15 GAIN 20 15 0 0 VOLUME MID 0 BASS 15 15 15 15 0 TREB 20 15...

Страница 8: ...INTERNET http www ecler com E mail info ecler es 50 0085 01 00 WIRING DIAGRAM ONE CHANNEL 100V 0V 300W 150W 80W AMPLIFIER OUTPUT MAX RMS AMPLIFIER OUTPUT POWER 4 OHM REAR PANEL DETAIL INPUT OUTPUT CHANNEL 2 70V 0V 100V 0V 0V 0V 100V 70V CHANNEL 1 OUTPUT INPUT 70V 0V A B GREEN 300W BROWN 150W BLUE 80W J107 For amplifier power selection connect the corresponding colour wires to A terminals of both c...

Отзывы: