![Ecler CA120HZ Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/ecler/ca120hz/ca120hz_user-manual_533322015.webp)
15
7.5. Micro switches on the rear panel
•
REMOTE
: Turn on (ON) the remote control from the WPmVOL or WPmVOL-SR
wall panel connected to the REMOTE port.
•
NOISE GATE
: Turn on (ON) or turn off the noise gate function for the microphone
input. When this function is active the microphone input is muted whilst there is no
signal above the function activation threshold, so the equipment rejects
background noise captured by the microphone connected to it.
•
TALKOVER
: (ON) or off according to the priority of the microphone over the line
inputs. When the TALKOVER function is on, the microphone signal will attenuate
to the line selected (LINE 1 or 2) when the activation threshold set is reached.
•
AUTO STANDBY
: Switch the AUTO STANDBY function on (ON) or off. When the
function is on, the CA40 will automatically go into STANDBY or low consumption
mode in the absence of audio signals in its inputs.
•
BRIDGE / MONO
(y
STEREO
): Select the work mode of the amplified outputs of
the unit:
o
BRIDGE
y
MONO OFF:
Work in stereo mode L / R
o
BRIDGE ON
(and
MONO
in
ON
or
OFF,
indistinctly): Work in bridge mode,
amplifying the L+R signal through both channels together as a single
amplifier with joint power.
o
BRIDGE OFF
y
MONO ON:
Work in MONO mode, both channels
independent and each of them amplifying the L+R signal.