background image

 

50-0243-01

06

 

CA40 EN 

 

 

 

CA40 

COMPACT AMPLIFIER 

AV Integration Micro-amplifier 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

 

Содержание CA120HZ

Страница 1: ...50 0243 0106 CA40 EN CA40 COMPACT AMPLIFIER AV Integration Micro amplifier USER MANUAL ...

Страница 2: ...ections 9 6 5 Remote control options 9 OPERATION AND USAGE 11 7 1 Start up and default mode 11 7 2 Special active source selection mode and setting adjustments 11 7 3 AUTO STANDBY Function 13 7 4 LED indicators 14 7 5 Micro switches on the rear panel 15 7 6 Lock mode 16 7 7 Restore default settings and update firmware 16 CLEANING 16 DIAGRAMS and LIST OF FUNCTIONS 17 BLOCK DIAGRAM 18 CONFIGURATION ...

Страница 3: ...sk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outlet with a protective earthing connection IMPORTANT SAFETY INSTRUCTION...

Страница 4: ...done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of the unit 17 The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shal...

Страница 5: ...th a 3 year warranty COMPLIANCE WITH INTERNATIONAL STANDARDS The CA40 micro amplifier complies with the following international standards EN55103 1 Electromagnetic Compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emission EN55103 2 Electromagnetic Compatibility Product family standard for audio video audio v...

Страница 6: ... consumption Lightweight silent high performance amplifier fan free convection cooling Suitable for stereo parallel and bridged mono operation 1 balanced microphone input with high quality preamplifier Phantom power supply noise gate and talkover function or priority over the rest of the input 2 stereo lines not balanced 2 band independent tone control Bass Treble for the microphone in jack and 1 ...

Страница 7: ...le shelf cupboard etc thanks to its design and layout of its connectors controls and LED indicator lights 6 2 Mains connection The amplifier is powered by alternating current through its external power source 100 240 VAC and 50 60 Hz This apparatus must be earthed through its mains cable earth resistance Rg 30 or lower The atmosphere should be as dry and dust free as possible Do not expose the uni...

Страница 8: ...ave an RIAA preamp The CA40 has the following operating modes according to the input sources selected as active LINE 1 only LINE 1 input is sent to the mix bus to be amplified and delivered to the L and R OUT outputs LINE 2 only LINE 2 is sent to the mix bus to be amplified and delivered to the L and R OUT outputs MIC only microphone MIC input is sent to the mix bus to be amplified and delivered t...

Страница 9: ...rs Additionally the CA40 has an unamplified auxiliary output AUX OUT which makes it possible to connect it to amplifiers or with other external devices The auxiliary output AUX OUT has a line level signal 0dBV which is an unamplified replica of the signal delivered to the terminals OUTPUT L y R 6 5 Remote control options REMOTE port the RJ 45 REMOTE type connector allows the connection of a WPmVOL...

Страница 10: ... supporting this protocol See the CA NET protocol manual for detailed information on the connection and syntax of the commands supported The connection has the following specifications o Baud rate 9600 fixed without auto negotiation o Data bits 8 o Parity None o Stop bits 1 o Flow control None Receiver IR the built in IR receiver gives general volume control of the CA40 and its MUTE ON OFF functio...

Страница 11: ...ing When the controller is turned to the left or to the right this flashes while the output volume increases or decreases The light stops flashing when it reaches either end of the scale and it is no longer possible to increase or decrease the volume of the unit Quickly press the VOL MUTE controller to activate deactivate the mute function of the unit MUTE ON OFF The MUTE LED lits when the mute fu...

Страница 12: ...is in special mode for 10 seconds and the front knob is not touched the equipment automatically reverts to VOL MUTE mode 2 In tone control mode when you turn the knob in either direction it flashes fast while the gain of the affected tone increases When either end of the scale is reached 10 ó 10dB or when it goes through the centre point 0dB it flashes more slowly ...

Страница 13: ...0 leaves standby mode and starts operating normally again and the ON STBY LED goes green When you enable AUTO STANDBY mode with the micro switch position ON one of two things happens a There is NO audio signal in the inputs Result the amplifier immediately goes into AUTO STANDBY mode b There is an audio signal in the inputs Result the amplifier stays active When the amplifier goes into AUTO STANDB...

Страница 14: ...active silent mode ON STBY the green light comes on when the equipment is in normal operating mode and it goes orange when it is in standby or low consumption mode STANDBY LEVEL This flashes when you adjust the general level of the device It also lights up during special adjustment modes input levels see section 7 2 Special active source selection mode and setting adjustments BASS This lights up d...

Страница 15: ... TALKOVER function is on the microphone signal will attenuate to the line selected LINE 1 or 2 when the activation threshold set is reached AUTO STANDBY Switch the AUTO STANDBY function on ON or off When the function is on the CA40 will automatically go into STANDBY or low consumption mode in the absence of audio signals in its inputs BRIDGE MONO y STEREO Select the work mode of the amplified outp...

Страница 16: ...e until the VOL MUTE control is held in for 10 seconds again 7 7 Restore default settings and update firmware If you would like to restore the CA40 to factory settings follow this procedure 1 Switch off the equipment then press and hold the knob in 2 Switch the unit back on without releasing the knob The MUTE LED indicator will flash 3 Wait a few seconds and then switch the CA40 off again 4 The ne...

Страница 17: ...ontrol receiver 13 REMOTE micro switch 14 NOISE GATE micro switch 15 TALKOVER micro switch 16 AUTO STANDBY micro switch 17 BRIDGE STEREO micro switch 18 MONO STEREO micro switch 19 DC24V power connector 20 MUTE remote control 21 RJ 45 REMOTE connector 22 OUT L amplified output 23 OUT R amplified output 24 Remote control by protocol CA NET RS 232 25 Mini jack input line LINE 1 26 Microphone input M...

Страница 18: ...18 BLOCK DIAGRAM CONFIGURATION DIAGRAM Phantom 0dB 6dB on Sensitivity 1 off Test 1 1 1 1 1 1 1 Sensitivity 6dB Phantom ON JUMPERS FACTORY ADJUST ...

Страница 19: ...m Load AUX OUT 6dBV 10kΩ Tone control LINE MIC BASS 100Hz 10dB TREBLE 6KHz 10dB Signal Noise Ratio LINE 85dB MIC BAL 65dB Talkover TIME 2 Sec DEPTH 30dB Microphone Noise Gate 40dB below max Phantom voltage 24VDC 10mA max RS232 BAUD RATE 9600 fixed DATA 8 bits PARITY NONE STOP BITS 1 FLOW CTRL NONE ANALOGUE REMOTE 0 10V based Volume Input selection INFRARED REMOTE Volume Mute Mains using Meanwell G...

Страница 20: ... protocol is simple and direct syntax friendly making it easy to read write and modify the generated code It is based on messages with no begin delimiter each message is self delimited by the RS232 packet size which is defined with a maximum of 80 ASCII characters and always including the character LF 0x0A at the end of each message All the messages must be written in CAPITAL LETTERS To let some c...

Страница 21: ...e associated DATA command via its RS 232 interface to keep synchronisation with the client device CA40 CA120 including CA120HZ and CA200z NOTES A couple of special parameters for the GET and SET commands would require a detailed explanation 1 AUTOLOAD_PRESET1 its value ON OFF defines whether preset number 1 must be recalled or not each time the CA device is powered ON defining this way the default...

Страница 22: ...just 3 20 25 30 It defines a value in a scale equivalent to 20 25 30 dB below the nominal level value for a given audio input If the numerical value is not in this list the unit will reply with an error message Depth Level the allowed numerical values in this field are just 4 20 30 60 80 It defines a value in a scale equivalent to 20 30 60 80 dB If the numerical value is not in this list the unit ...

Страница 23: ...here are two independent REMOTE ports each one able to control one of the device s outputs when the CA200z has been configured in the ZONES A B mode Each selector can be used in any of these 3 modes o INPUTS to select the active audio LINE source OFF LINE1 LINE2 LINE3 or LINE4 o PRESETS to recall any of the 5 presets in the memory of the unit which store the full configuration of the unit includin...

Страница 24: ...thout blank spaces that identify the LCD display working mode In the CA200z there are just three possible values for this parameter o ON o DIMMED o OFF Contrast Level are numerical values in the 0 100 range that define the LCD display contrast level Assign Value are text strings without blank spaces that identify the Talkover Pager function assignment for a MIC input towards the device s outputs I...

Страница 25: ...tion zones o IN_SEL_ZONE_VOL one input source selection for one or several output zones with the 5 position selector the control of the affected zones output volume o PRESET a preset recovery from P1 to P5 with the 5 position selector o PRESET_ZONE_VOL a preset recovery from P1 to P5 with the 5 position selector volume control for one or several zone outputs o MATRIX_VOL PAGER DUCKER parameter for...

Страница 26: ...he current LINE1 TREBLE LEVEL LINE2_TREBLE Gets the current LINE2 TREBLE LEVEL MICRO_TREBLE Gets the current MICRO TREBLE LEVEL GATE Gets the current NOISE GATE ON OFF status GATE_THRESHOLD Gets the current NOISE GATE THRESHOLD LEVEL TALKOVER Gets the current TALKOVER ON OFF status TALKOVER_THRESHOLD Gets the current TALKOVER THRESHOLD LEVEL TALKOVER_ATTACK Gets the current TALKOVER ATTACK TIME TA...

Страница 27: ...INE2 TREBLE LEVEL MICRO_TREBLE Tone Level Sets the current MICRO TREBLE LEVEL GATE_THRESHOLD Threshold Level Sets the current NOISE GATE THRESHOLD LEVEL TALKOVER_THRESHOLD Threshold Level Sets the current TALKOVER THRESHOLD LEVEL TALKOVER_ATTACK Attack Time Value Sets the current TALKOVER ATTACK TIME TALKOVER_RELEASE Release Time Value Sets the current TALKOVER RELEASE TIME TALKOVER_DEPTH Depth Le...

Страница 28: ...urrent NOISE GATE ON OFF status GATE_THRESHOLD Threshold Level Shows the current NOISE GATE THRESHOLD LEVEL TALKOVER ON OFF Shows the current TALKOVER ON OFF status TALKOVER_THRESHOLD Threshold Level Shows the current TALKOVER THRESHOLD LEVEL TALKOVER_ATTACK Attack Time Value Shows the current TALKOVER ATTACK TIME TALKOVER_RELEASE Release Time Value Shows the current TALKOVER RELEASE TIME TALKOVER...

Страница 29: ...3_BASS Gets the current MICL3 BASS LEVEL LINE1_TREBLE Gets the current LINE1 TREBLE LEVEL LINE2_TREBLE Gets the current LINE2 TREBLE LEVEL MICL3_TREBLE Gets the current MICL3 TREBLE LEVEL GATE Gets the current NOISE GATE ON OFF status GATE_THRESHOLD Gets the current NOISE GATE THRESHOLD LEVEL TALKOVER Gets the current TALKOVER ON OFF status TALKOVER_THRESHOLD Gets the current TALKOVER THRESHOLD LE...

Страница 30: ... Tone Level Sets the current LINE2 TREBLE LEVEL MICL3_TREBLE Tone Level Sets the current MICL3 TREBLE LEVEL GATE_THRESHOLD Threshold Level Sets the current NOISE GATE THRESHOLD LEVEL TALKOVER_THRESHOLD Threshold Level Sets the current TALKOVER THRESHOLD LEVEL TALKOVER_ATTACK Attack Time Value Sets the current TALKOVER ATTACK TIME TALKOVER_RELEASE Release Time Value Sets the current TALKOVER RELEAS...

Страница 31: ...VEL GATE ON OFF Shows the current NOISE GATE ON OFF status GATE_THRESHOLD Threshold Level Shows the current NOISE GATE THRESHOLD LEVEL TALKOVER ON OFF Shows the current TALKOVER ON OFF status TALKOVER_THRESHOLD Threshold Level Shows the current TALKOVER THRESHOLD LEVEL TALKOVER_ATTACK Attack Time Value Shows the current TALKOVER ATTACK TIME TALKOVER_RELEASE Release Time Value Shows the current TAL...

Страница 32: ...for the specified INPUT at the specified ZONE BASS Input Name Zon e Gets the current BASS LEVEL for the specified INPUT at the specified ZONE TREBLE Input Name Zon e Gets the current TREBLE LEVEL for the specified INPUT at the specified ZONE GATE Micro Name Gets the current NOISE GATE status ON or OFF for the specified MIC INPUT GATE_THRESHOLD Micro Name Gets the current NOISE GATE THRESHOLD LEVEL...

Страница 33: ...the specified ZONE IR_REMOTE Gets the current IR REMOTE status ON or OFF DISPLAY_MODE Gets the current DISPLAY MODE LCD_CONTRAST Gets the current DISPLAY CONTRAST level AUTO_STANDBY Gets the current AUTO STANDBY function status ON or OFF AUTOLOAD_PRESET1 Gets the current AUTOLOAD_PRESET1 at Startup function PANEL_LOCKED Gets the current PANEL_LOCKED front panel controls status INFO_MODEL Gets the ...

Страница 34: ...d INPUT at the specified ZONE GATE Micro Name ON OFF Sets the current NOISE GATE status ON or OFF for the specified MIC INPUT GATE_THRESHOL D Micro Name Threshold Level Sets the current NOISE GATE THRESHOLD LEVEL for the specified MIC INPUT TALKOVER_ASSIG N Micro Name Assign Value Sets the current TALKOVER ASSIGN for the specified MIC INPUT TALKOVER_PRIORI TY Micro Name Priority number Sets the cu...

Страница 35: ...r OFF DISPLAY_MODE Display Mode Sets the current DISPLAY MODE LCD_CONTRAST Contrast Level Sets the current DISPLAY CONTRAST level AUTO_STANDBY ON OFF Sets the current AUTO STANDBY function status ON or OFF AUTOLOAD_PRES ET1 ON OFF Sets the current AUTOLOAD_PRESET1 at Startup function PANEL_LOCKED ON OFF Sets the current PANEL_LOCKED front panel controls status ...

Страница 36: ... for the specified INPUT at the specified ZONE TREBLE Input Name Tone Level Zone Shows the current TREBLE LEVEL for the specified INPUT at the specified ZONE GATE Micro Name ON OFF Shows the current NOISE GATE status ON or OFF for the specified MIC INPUT GATE_THRESHOL D Micro Name Threshold Level Shows the current NOISE GATE THRESHOLD LEVEL for the specified MIC INPUT TALKOVER_ASSIG N Micro Name A...

Страница 37: ...ON Firmware Version Shows the current Firmware Version DAM514 TYPE PARAM1 PARAM2 PARAM3 PARAM 4 DESCRIPCIÓN GET ALL Dumps current device status with DATA messages INFO_MODEL Gets the Device model name INFO_VERSION Gets the current Firmware Version AUTOLOAD_PRESET1 Gets the current AUTOLOAD_PRESET1 at Startup function PRESET_NUMBER Gets the current PRESET number PRESET_NAME Preset P1 P20 Preset T1 ...

Страница 38: ...REBLE tone LEVEL for the specified INPUT HPF_ACTIVE Input I4 I5 Gets the current HIGH PASS FILTER status ON or OFF for the specified INPUT HPF_FREQUENCY Input I4 I5 Gets the current HIGH PASS FILTER frequency Hz for the specified INPUT FBS_ACTIVE Input I4 I5 Gets the current FEEDBACK SUPPRESSOR feature status ON or OFF for the specified INPUT GATE_ACTIVE Input I4 I5 Gets the current NOISE GATE sta...

Страница 39: ...e specified INPUT TALKOVER_HOLD Input I4 I5 Gets the current TALKOVER HOLD TIME milliseconds x10 for the specified INPUT TALKOVER_RELEASE Input I4 I5 Gets the current TALKOVER RELEASE TIME milliseconds x10 for the specified INPUT CHIME_MELODY Input I4 I5 Gets the current CHIME MELODY selected for the TALKOVER function in PAGER mode CHIME_VOL Input I4 I5 Gets the current CHIME MELODY VOLUME dBx10 a...

Страница 40: ...d output zone GEQ_GAIN Zone ZA ZD Band B1 B10 Gets the current GAIN dBx10 of one BAND B1 to B10 of the GRAPHICAL EQUALIZER for the specified output zone XOVER_ACTIVE Zone ZA ZD Gets the current CROSSOVER FILTER status ON or OFF for the specified output zone XOVER_TYPE Zone ZA ZD Gets the current CROSSOVER FILTER TYPE LP or HP for the specified output zone XOVER_FREQUENCY Zone ZA ZD Gets the curren...

Страница 41: ... R1 to R4 Inputs parameter can include I1 to I5 separated by comma characters and no blank space example I1 I2 I3 REMOTE_ZONES Remote R1 R4 Zones ZA ZD Sets the list of outputs affected by the working mode of a certain REMOTE port from R1 to R4 Zones parameter can include ZA to ZD separated by comma characters and no blank space example ZA ZC ZD DISPLAY_MODE DisplayMode Sets the current LCD DISPLA...

Страница 42: ...E GATE THRESHOLD LEVEL dBx10 for the specified INPUT GATE_DEPTH Input I4 I5 Depth dBx10 Sets the current NOISE GATE DEPTH attenuation when gate is closed dBx10 for the specified INPUT GATE_ATTACK Input I4 I5 AttackTime msx10 Sets the current NOISE GATE ATTACK TIME milliseconds x10 for the specified INPUT GATE_HOLD Input I4 I5 HoldTime msx10 Sets the current NOISE GATE HOLD TIME milliseconds x10 fo...

Страница 43: ...OFF Sets the current CROSSPOINT SELECT status ON input active or OFF input muted for the specified INPUT at the specified output zone XLEVEL Input I1 I5 Zone ZA ZD Level 0 99 Sets the current CROSSPOINT LEVEL mix level for the specified INPUT at the specified output zone ZONE_LABEL Zone ZA ZD Label Sets the current LABEL name for the specified output zone between quotation marks to allow for blank...

Страница 44: ... T6 Shows that the last SET LOAD_PRESET or SET PRESET_NUMBER command has been processed the preset is loaded and active REMOTE_MODE Remote R1 R4 RemoteMode Shows the working mode for a certain REMOTE port from R1 to R4 REMOTE_INPUTS Remote R1 R4 Inputs I1 I5 Shows the list of inputs affected by the working mode of a certain REMOTE port from R1 to R4 REMOTE_ZONES Remote R1 R4 Zones ZA ZD Shows the ...

Страница 45: ...CTIVE Input I4 I5 ON OFF Showss the current NOISE GATE status ON or OFF for the specified INPUT GATE_THRESHOLD Input I4 I5 Threshold dBx10 Shows the current NOISE GATE THRESHOLD LEVEL dBx10 for the specified INPUT GATE_DEPTH Input I4 I5 Depth dBx10 Shows the current NOISE GATE DEPTH attenuation when gate is closed dBx10 for the specified INPUT GATE_ATTACK Input I4 I5 AttackTime ms Shows the curren...

Страница 46: ...nput I4 I5 Volume dBx10 Shows the current CHIME VOLUME dBx10 adjusted for the TALKOVER function in PAGER mode XSELECT Input I1 I5 Zone ZA ZD ON OFF Shows the current CROSSPOINT SELECT status ON input active or OFF input muted for the specified INPUT at the specified output zone XLEVEL Input I1 I5 Zone ZA ZD Level 0 99 Shows the current CROSSPOINT LEVEL mix level for the specified INPUT at the spec...

Страница 47: ...ID Input I1 I5 Count Increments decrements a certain INPUT s current MIDDLE tone LEVEL The increment applied is defined by the Count parameter dBx10 IN_TREBLE Input I1 I5 Count Increments decrements a certain INPUT s current TREBLE tone LEVEL The increment applied is defined by the Count parameter dBx10 XLEVEL Input I1 I5 Zone ZA ZD Count Increments decrements a certain CROSSPOINT current VOLUME m...

Страница 48: ...rror 1 Invalid field TYPE 2 Invalid field PARAM1 3 Invalid field PARAM2 4 Invalid field PARAM3 5 Invalid field PARAM4 9 Rejected Message 10 Message too long more than 80 characters 11 Unsupported Preset number 17 Invalid Level value ...

Страница 49: ...t LCD DISPLAY MODE LCD_CONTRAST Gets the current LCD DISPLAY CONTRAST level EXT_MUTE_ZONES Gets the outputs to be muted by an external contact closure connected to the MUTE port IN_LABEL Input I1 I6 Gets the current LABEL name for the specified INPUT IN_STEREO Input I3 I6 Gets the current STEREO link status ON or OFF for INPUTs 3 and 4 IN_MUTE Input I1 I6 Gets the current MUTE status ON or OFF for...

Страница 50: ...T TALKOVER_ACTIVE Input I3 I6 Gets the current TALKOVER status ON or OFF for the specified INPUT TALKOVER_MODE Input I3 I6 Gets the TALKOVER function working mode PAGER or DUCKER for the specified INPUT TALKOVER_PRIORITY Input I3 I6 Gets the current TALKOVER PRIORITY level LOW or HIGH for the specified INPUT TALKOVER_ZONES Input I3 I6 Gets the current TALKOVER assignment to outputs ZONES for the s...

Страница 51: ... the current GRAPHICAL EQUALIZER status ON or OFF for the specified output zone GEQ_GAIN Zone ZA ZD Band B1 B10 Gets the current GAIN dBx10 of one BAND B1 to B10 of the GRAPHICAL EQUALIZER for the specified output zone XOVER_ACTIVE Zone ZA ZD Gets the current CROSSOVER FILTER status ON or OFF for the specified output zone XOVER_TYPE Zone ZA ZD Gets the current CROSSOVER FILTER TYPE LP or HP for th...

Страница 52: ... output zone COMPRESSOR_GAIN Zone ZA ZD Gets the current COMPRESSOR GAIN dBx10 for the specified output zone DELAY_ACTIVE Zone ZA ZD Gets the current DELAY status ON or OFF for the specified output zone DELAY_TIME Zone ZA ZD Gets the current DELAY TIME milliseconds x10 for the specified output zone ...

Страница 53: ...he working mode of a certain REMOTE port from R1 to R4 Inputs parameter can include I1 to I6 separated by comma characters and no blank space example I1 I2 I3 REMOTE_ZONES Remote R1 R4 Zones ZA ZD Sets the list of outputs affected by the working mode of a certain REMOTE port from R1 to R4 Zones parameter can include ZA to ZD separated by comma characters and no blank space example ZA ZC ZD DISPLAY...

Страница 54: ...VE Input I3 I6 ON OFF Sets the current NOISE GATE status ON or OFF for the specified INPUT GATE_THRESHOLD Input I3 I6 Threshold dBx10 Sets the current NOISE GATE THRESHOLD LEVEL dBx10 for the specified INPUT GATE_DEPTH Input I3 I6 Depth dBx10 Sets the current NOISE GATE DEPTH attenuation when gate is closed dBx10 for the specified INPUT GATE_ATTACK Input I3 I6 AttackTime msx10 Sets the current NOI...

Страница 55: ...Sets the current CHIME MELODY selected for the TALKOVER function in PAGER mode CHIME_VOL Input I3 I6 Volume dBx10 Sets the current CHIME MELODY VOLUME dBx10 adjusted for the TALKOVER function in PAGER mode XSELECT Input I1 I6 Zone ZA ZD ON OFF Sets the current CROSSPOINT SELECT status ON input active or OFF input muted for the specified INPUT at the specified output zone XLEVEL Input I1 I6 Zone ZA...

Страница 56: ...SSOR THRESHOLD LEVEL dBx10 for the specified output zone COMPRESSOR_RATIO Zone ZA ZD Ratio x100 Sets the current COMPRESSOR RATIO x100 for the specified output zone COMPRESSOR_ATTACK Zone ZA ZD AttackTime msx10 Sets the current COMPRESSOR ATTACK TIME milliseconds x10 for the specified output zone COMPRESSOR_RELEASE Zone ZA ZD ReleaseTime msx10 Sets the current COMPRESSOR RELEASE TIME milliseconds ...

Страница 57: ...hows the working mode for a certain REMOTE port from R1 to R4 REMOTE_INPUTS Remote R1 R4 Inputs I1 I6 Shows the list of inputs affected by the working mode of a certain REMOTE port from R1 to R4 REMOTE_ZONES Remote R1 R4 Zones ZA ZD Shows the list of outputs affected by the working mode of a certain REMOTE port from R1 to R4 DISPLAY_MODE DisplayMode Shows the current DISPLAY MODE LCD_CONTRAST Cont...

Страница 58: ...ESHOLD Input I3 I6 Threshold dBx10 Shows the current NOISE GATE THRESHOLD LEVEL dBx10 for the specified INPUT GATE_DEPTH Input I3 I6 Depth dBx10 Shows the current NOISE GATE DEPTH attenuation when gate is closed dBx10 for the specified INPUT GATE_ATTACK Input I3 I6 AttackTime ms Shows the current NOISE GATE ATTACK TIME milliseconds x10 for the specified INPUT GATE_HOLD Input I3 I6 HoldTime ms Show...

Страница 59: ...T Input I1 I6 Zone ZA ZD ON OFF Shows the current CROSSPOINT SELECT status ON input active or OFF input muted for the specified INPUT at the specified output zone XLEVEL Input I1 I6 Zone ZA ZD Level 0 99 Shows the current CROSSPOINT LEVEL mix level for the specified INPUT at the specified output zone ZONE_LABEL Zone ZA ZD Label Shows the current LABEL name for the specified output zone ZONE_STEREO...

Страница 60: ...100 for the specified output zone COMPRESSOR_ATTACK Zone ZA ZD AttackTime msx10 Shows the current COMPRESSOR ATTACK TIME milliseconds x10 for the specified output zone COMPRESSOR_RELEASE Zone ZA ZD ReleaseTime msx10 Shows the current COMPRESSOR RELEASE TIME milliseconds x10 for the specified output zone COMPRESSOR_KNEE Zone ZA ZD SOFT HARD Shows the current COMPRESSOR KNEE mode SOFT or HARD for th...

Страница 61: ...efined by the Count parameter dBx10 IN_TREBLE Input I1 I6 Count Increments decrements a certain INPUT s current TREBLE tone LEVEL The increment applied is defined by the Count parameter dBx10 XLEVEL Input I1 I6 Zone ZA ZD Count Increments decrements a certain CROSSPOINT current VOLUME matrix level sent from one input to one output The increment applied is defined by the Count parameter dBx10 ZONE_...

Страница 62: ...ght to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on our website in Support Technical requests Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...