background image

 

 

IMPORTANT REMARK 

 

 

The lightning flash with arrowhead symbol, within an equilateral triangle, is 

intended  to  alert  the  user  to  the  presence  of  uninsulated  “ dangerous 

voltage”  within the product’s enclosure that may be of sufficient magnitude 

to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is intended to alert the user to the 

presence of important operating and maintenance (servicing) instructions in 

the literature accompanying the appliance. 

WARNING (If applicable):

 

The  terminals  marked  with  symbol  of  “

”  

may be of sufficient magnitude to constitute a risk of electric shock. The external wiring 

connected to the terminals requires installation by an instructed person or the use of 

ready-made leads or cords. 

WARNING

:

 To prevent fire or shock hazard, do not expose this equipment to rain or 

moisture. 

WARNING

:

  An  apparatus  with  Class  I  construction  shall  be  connected  to  a  mains 

socket-outlet with a protective earthing connection.  

 

IMPORTANT SAFETY INSTRUCTIONS 

1.

 

Read these instructions.

 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do  not  block  any  ventilation  openings.  Install  in  accordance  with  the 

manufacturer’s instructions.

 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 

other apparatus (including amplifiers) that produce heat. 

 

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 

polarized plug has two blades with one wider than the other. A grounding type 

plug has two blades and a third grounding prong. The wide blade or the third 

prong are provided for your safety. If the provided plug does not fit into your 

outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect  the  power  cord  from  being  walked  on  or  pinched  particularly  at  the 

plugs,  convenience  receptacles,  and  at  the  point  where  they  exit  from  the 

apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods 

of time. 

Содержание ARQISi Series

Страница 1: ...v 20210722 ARQISi Series CABINET LOUDSPEAKERS Architectural Loudspeaker Cabinets USER MANUAL...

Страница 2: ...5 10 ARQISSB12i 9 5 11 ARQISSB15i 9 CONNECTIONS 10 6 1 ARQISSB6Ti 10 EQ SETTINGS 11 RECOMMENDED AMPLIFIER 11 POSITIONING 11 INSTALLATION 12 TECHNICAL SPECIFICATIONS 13 INSTALLATION DIAGRAMS 18 CONTEN...

Страница 3: ...tive earthing connection IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean...

Страница 4: ...limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen...

Страница 5: ...balance the sound across the entire range improve frequency response increase power ARQIS110i ARQIS112i and add a new subwoofer model ARQISSB12i The 105 106 and 108 models include a new wall bracket V...

Страница 6: ...justment employing a single screw for fastening Robust quick and easy to install including jumps and markings for repeating speaker orientation Metal safety sling included to avoid drops in case of ac...

Страница 7: ...case of accidental detachment from the wall surface Available in black RAL9005 or white RAL9003 finish 5 5 ARQIS208i Full range 2 way architectural loudspeaker 300 WRMS 8 2 x 8 woofer 1 compression dr...

Страница 8: ...udspeaker 500 WRMS 8 1 x 12 woofer 1 compression driver rotable Double INPUT STACK connector Euroblock Speakon type with security attachment screws to avoid accidental disconnection 35 mm mount socket...

Страница 9: ...ace mount subwoofer 300 WRMS 8 ohm 10 woofer Euroblock connector and spring loaded input terminals LPF cut off frequency selection OFF 120Hz 150Hz Wall mount hardware included 12 x M8 cabinet flying p...

Страница 10: ...econd connector Euroblock or Speakon depending on model thereby facilitating the parallel connection of speakers 6 1 ARQISSB6Ti ARQISSB6Ti supports high or low impedance operation In this matter it ha...

Страница 11: ...ECOMMENDED AMPLIFIER Following table shows the output power of the amplifier adequate to each acoustic system ARQIS105i 140W RMS ARQIS106i 240W RMS ARQIS108i 300W RMS ARQIS205i 280W RMS ARQIS208i 600W...

Страница 12: ...ssion driver ARQIS205 ARQIS208 ARQIS110 ARQIS 112 ARQISSB10 ARQISSB15 also have built in M8 rigging points for suspension from a compatible structure or truss using steel cables IMPORTANT NOTE The equ...

Страница 13: ...M6 2 x M8 Operating temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Operating humidity 85 HR 85 HR 85 HR Storage temperature Min 10 C 14 F Max 40 C 1...

Страница 14: ...x M8 4x M6 12 x M8 Operating temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Operating humidity 85 HR 85 HR Storage temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40...

Страница 15: ...crew fixation Flying points 12 x M8 12 x M8 Operating temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Operating humidity 85 HR 85 HR Storage temperature Min 10 C 14 F Max 40 C 10...

Страница 16: ...ints 2 x M8 2 x M8 Operating temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Operating humidity 85 HR 85 HR Storage temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40...

Страница 17: ...x M8 Operating temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Operating humidity 85 HR 85 HR Storage temperature Min 10 C 14 F Max 40 C 104 F Min 10 C 14 F Max 40 C 104 F Storag...

Страница 18: ...18 INSTALLATION DIAGRAMS Mounting the VEASY wall bracket ARQIS105i ARQIS106I ARQIS108i...

Страница 19: ...19...

Страница 20: ...2 ARQIS series installation Example of horizontal and vertical installation using the included flying points or the U bracket included in 205i 208i and SB6Ti models optional for 108i 110i and 112i mo...

Страница 21: ...card 12 2 ARQIS106i 1 x ARQIS106i loudspeaker 1 x VEASY wall bracket with vertical and horizontal adjustment VESA compatible 1 x Allen key 3mm 1 x Allen key 4mm 1 x Allen key 6mm 2x Euroblock Quick u...

Страница 22: ...208i 1 x ARQIS208i loudspeaker 1 x U shaped wall ceiling bracket Metal security handle 1 x Allen key 5mm 1 x Allen key 6mm 2 x screws 2 x washers 2 x rubber washers 2 x plastic trims 1 x Euroblock 1 x...

Страница 23: ...x Euroblock 1 x Speakon Quick user guide Warranty card 12 9 ARQISSB10i 1 x ARQISSB10i loudspeaker 1 x wall mounting bracket 4 x screws 4 x rubber feet 1 x Euroblock Quick user guide Warranty card 12 1...

Страница 24: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Отзывы: