11
impedance of the full assembly. Moreover, this solution enables long cable runs with
significantly smaller sections that those usually employed in low-impedance
installations, but with minimum power losses.
WARNING!
If the system is accidentally connected with the switch in the 100 V/60 W
position to a low-impedance amplifier, no damage will be caused to the loudspeaker,
but its performance will be well below its specifications. If the loudspeaker is
accidentally connected to a 70 V/100 V network, in the 8
Ω
position, it will be seriously
damaged.
EQ SETTINGS
file for ARQIS105i, ARQIS106i, ARQIS108i,
ARQIS110i, ARQIS112i, ARQIS205i and ARQIS208i, ready to import in EclerNet
Manager software.
RECOMMENDED AMPLIFIER
Following table shows the output power of the amplifier adequate to each acoustic
system:
•
ARQIS105i: 140W RMS
•
ARQIS106i: 240W RMS
•
ARQIS108i: 300W RMS
•
ARQIS205i: 280W RMS
•
ARQIS208i: 600W RMS
•
ARQIS110i: 600W RMS
•
ARQIS112i: 1000W RMS
•
ARQISSB6Ti: 240WRMS @ 8Ω
•
ARQISSB10i: 300W RMS
•
ARQISSB12i: 600W RMS
•
ARQISSB15i: 1200W RMS
POSITIONING
Consider following general rules:
Place the speakers on a solid and firm surface. Subwoofers placed directly and
horizontally on the ground have a higher output than hanged or directly on the floor,
but vertically. No obstacles should stand between the enclosures and the audience. The
high frequencies are very directive compared to the low frequencies, so that any
obstacle will impair their response. In case large audiences must be addressed, a better
long distance sound propagation will be achieved if the enclosures are flown high
enough.
Download all EASE files by clicking on the image: