eMCONTROL1 

REMOTE

 

CONTROLS

 

AND

 

INTERFACES

 

Digital wall control 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

 

 

 

 

Содержание eMCONTROL1

Страница 1: ...eMCONTROL1 REMOTE CONTROLS AND INTERFACES Digital wall control USER MANUAL ...

Страница 2: ...NT NOTE 5 4 INTRODUCTION 5 5 INSTALLATION 6 6 OPERATING THE UNIT 8 6 1 Controls 8 6 2 Equalization screen 9 6 3 Information messages 10 7 NOTES 12 8 FRONT PANEL 13 9 BACK PANEL 13 10 BLOCK DIAGRAM 14 11 TECHNICAL SPECIFICATIONS 14 12 MOUNTING DRAWINGS 15 13 PACKAGE CONTENTS 16 ...

Страница 3: ...sk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING to prevent electric shock or fire hazard do not expose this equipment to rain or moisture WARNING apparatus with Class I construction must be connected to...

Страница 4: ...ightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Mains disc...

Страница 5: ...16 It allows you to configure source selection volume control and equalization for a given zone including all or some of the functions It can be combined with a WPa series wall panel connecting both with a single CAT5 cable or better to the eMIMO1616 transmitting the mono and balanced audio signal line level along with the necessary control data and DC power supply The main features of the eMCONTR...

Страница 6: ...allation box is required to flush mount the two devices side by side Otherwise for surface mounting a WPa2SMBOX dual box is required Both WPa2FMBOX and WPa2SMBOX are sold separately 1 Remove the front panel covers held by magnets on both devices eMCONTROL1 and WPaMIX T You can use the magnet provided as a tool to make contact in the upper right hand corner of the cover and gently pull on it 2 Moun...

Страница 7: ...ters If the cable is too long eMCONTROL1 may work properly but noise will be superimposed on the signal entering the WPaMIX T The solution to this possible problem is to supply the eMCONTROL1 digital control with an external 24VDC power supply The digital data exchange between the eMIMO1616 unit and the eMCONTROL1 unit using external power supply and good quality CAT5E cable has been successfully ...

Страница 8: ... on its front panel Rotating Encoder Selection key Figure 2 Front panel controls The main screen displays the label or name of the controlled zone the source selection in that zone and its volume control Figure 3 main screen Zone name Selected source Zone volume ...

Страница 9: ...ding to each source will start flashing Press the encoder to select the desired source and apply the change After a few seconds without selecting a source the previous state is restored without any change being applied The eMIMO1616 application determines available sources see the eMIMO1616 web application manual for more information 6 2 Equalization screen The equalization screen is accessed by h...

Страница 10: ...ion Figure 5 information screen The firmware version is automatically updated when connecting to an eMIMO1616 ensuring you have the latest compatible version Therefore eMCONTROL1 does not require manual firmware updates See chapter 7 for more information DISABLED displayed when the device is disabled Unit global enable eMIMO1616 web application Figure 6 Disabled screen OFFLINE displayed when the d...

Страница 11: ... and rotary encoder for approx 5 seconds After 2 seconds the information screen will be displayed but keep the controls pressed until the block message is displayed on the screen The unlocking is done with the same sequence of keys This hidden function is useful to temporarily protect the system from manipulation by unauthorized users e g during an event when you want to prevent the attendees from...

Страница 12: ...pdated and if so automatically performs update without external manual intervention This process takes a few seconds to be carried out while the message UPGRADING FIRMWARE will be displayed When connecting an eMPAGE paging station to the PAGER port of a running powered on eMIMO1616 unit it is normal to have to restart all other connected paging stations and eMCONTROL1 controllers a process that ta...

Страница 13: ...13 8 FRONT PANEL 9 BACK PANEL 1 Front panel faceplate 2 LCD screen 3 Selection button 4 Rotary encoder 1 External power supply connector 24VDC 2 Connector for WPaMIX T interconnection 3 RJ 45 connector ...

Страница 14: ... External Input 24VDC Minimum external power supply From RJ45 remote input without WPaMIX T 9 5V From RJ45 remote input with WPaMIX T 11V From External Input 18VDC Maximum power consumption From RJ45 remote input without WPaMIX T 60mA From RJ45 remote input with WPaMIX T 80mA From External Input 25mA 24VDC Miscellaneous Connector RJ45 remote port Dimensions W x H x D 86 x 86 x 45mm Weight 150g Inc...

Страница 15: ...15 12 MOUNTING DRAWINGS ...

Страница 16: ...S eMCONTROL1 Frame for mounting a mechanism in a system Screws for fixing to surface or flush mounting box Magnet for cover removal Surface mounting box Cable for direct connection to WPaMIX T Quick User Guide Warranty card ...

Страница 17: ...riation due to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make design or manufacturing changes that may affect these product specifications Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler es www ecler com ...