background image

 

 

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 
polarized plug has two blades with one wider than the other. A grounding type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong  are  provided  for  your  safety.  If  the  provided  plug  does  not  fit  into  your 
outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at the plugs, 
convenience receptacles, and at the point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods of 
time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 
apparatus has been damaged in any way, such as power supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or 
has been dropped.

 

14.

 

Disconnecting  from  mains:  When  switching  off  the  POWER  switch,  all  the 
functions and light indicators of the unit will be stopped, but fully disconnecting 
the device from mains is done by unplugging the power cable from the mains 
input socket. For this reason, it always shall remain easily accessible. 

15.

 

Equipment is connected to a socket-outlet with earthing connection by means of 
a power cord. 

16.

 

The marking information is located at the bottom of the unit. 

17.

 

The apparatus shall not be exposed to dripping or splashing and that no objects 
filled with liquids, such as vases, shall be placed on apparatus. 
 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class 

A  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 
operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction 
manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense. 

  

 

WARNING

:

 

This product must not be discarded, under any circumstance, as 

unsorted  urban  waste.  Take  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

NEEC AUDIO BARCELONA, S.L. 

accepts no liability for any damage that may be caused 

to people, animal or objects due to failure to comply with the warnings above. 

Содержание eCA120HZ

Страница 1: ...50 0287 0104 eCA120HZ EN eCA120HZ COMPACT AMPLIFIER High Impedance Micro amplifier USER MANUAL ...

Страница 2: ...ATION 7 6 1 Location and assembly 7 6 2 Mains connection 7 6 3 Audio input connections 8 6 4 Audio output connections 8 6 5 Remote control port 8 OPERATION AND USAGE 9 7 1 Start up 9 7 2 AUTO STANDBY Function 9 7 3 LED indicators 10 7 4 Setup jumpers 10 CLEANING 10 DIAGRAM and LIST OF FUNCTIONS 11 BLOCK DIAGRAM 12 CONFIGURATION DIAGRAM 12 TECHNICAL CHARACTERISTICS 13 ...

Страница 3: ...sk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outlet with a protective earthing connection IMPORTANT SAFETY INSTRUCTION...

Страница 4: ...done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of the unit 17 The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shal...

Страница 5: ...with a 3 year warranty COMPLIANCE WITH INTERNATIONAL STANDARDS The eCA120HZ micro amplifier complies with the following international standards EN55103 1 Electromagnetic Compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emission EN55103 2 Electromagnetic Compatibility Product family standard for audio video a...

Страница 6: ...5 1 Main characteristics 1 x 120 W RMS 70 100V high impedance Universal external power supply AUTO STANDBY function in the absence of an audio signal the unit automatically goes into STANDBY mode minimising power consumption Lightweight silent high performance amplifier fan free convection cooling 1 unbalanced stereo line input LINE IN STACK with dual RCA connector and 3 pin Euroblock connector Lo...

Страница 7: ... installation on a wall or under a surface table shelf cupboard etc thanks to its design and layout of its connectors controls and LED indicator lights 6 2 Mains connection The amplifier is powered by alternating current through its external power source 100 240 VAC and 50 60 Hz The atmosphere should be as dry and dust free as possible Do not expose the unit to rain or water splashes Do not place ...

Страница 8: ...The amplified output OUTPUT uses a Euroblock connector with a common terminal 0V a terminal for a 70V line and another terminal for a 100V line Always use the common terminal and depending on the type of speaker in the system one of the two others 70 or 100V to feed the loudspeaker line The connection cable that connects the eCA120HZ connectors and the speakers should be good quality with a suitab...

Страница 9: ...n mode means you can install the eCA120HZ in inaccessible places and leave the device connected to the mains power supply permanently because when no signal is detected it automatically goes into standby mode saving energy To enable the AUTO STANDBY mode the jumper labeled AUTO STBY on the front panel has to be in the ON position When it is enabled and after 2 minutes or more without any audio sig...

Страница 10: ...rval a few seconds the amplifier may go into protection mode being muted to return to normal operation in a short time ON STBY the green light comes on when the equipment is in normal operating mode and it goes orange when it is in standby or low consumption mode STANDBY 7 4 Setup jumpers REMOTE enables ON the remote volume control from a WPm type wall panel or another model of the WPm series conn...

Страница 11: ...cator light 2 DC24V power connector 3 CLIP indicator light 4 OUTPUT amplified signal 0V 70V 100V 5 SP input signal presence indicator light 6 VOLUME knob 7 Euroblock input line STACK 8 RCA input line LINE IN 9 RJ 45 REMOTE connector 10 REMOTE AUTO STANDBY jumpers ...

Страница 12: ...12 BLOCK DIAGRAM CONFIGURATION DIAGRAM ...

Страница 13: ...High Pass Filter Internal no removable 70Hz Signal Noise Ratio 85dB VOLUME at 0dB Remote control externally selectable Master Volume Analog 0 10V based Auto standby Time 2 minutes aprox Threshold 40dBV L R Mains using supplied DC adapter 100 240VAC External PSU 24VDC Power consumption pink noise 1 8 power 38VA 26W pink noise 1 3 power 61VA 51W Standby time 2 minutes 2 5W General Dimensions WxDxH 1...

Страница 14: ...ght to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on our website in Support Technical requests Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...

Отзывы: