IMPORTANT REMARK 

 

 

The lightning flash with arrowhead symbol, within an equilateral triangle, is 

intended to alert the user to the presence of uninsulated “dangerous voltage” 
within  the  product’s  enclosure  that  may  be  of  sufficient  magnitude  to 

constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is intended to alert the 
user  to  the  presence  of  important  operating  and  maintenance  (servicing) 
instructions in the literature accompanying the appliance. 

WARNING (If applicable):

 The 

terminals marked with symbol of “

” may be of 

sufficient magnitude to constitute a risk of electric shock. The external wiring connected 
to the terminals requires installation by an instructed person or the use of ready-made 
leads or cords. 

WARNING

:

 To prevent fire or shock hazard, do not expose this equipment to rain or 

moisture. 

WARNING

:

  An  apparatus  with  Class  I  construction  shall  be  connected  to  a  mains 

socket-outlet with a protective earthing connection.  

 

IMPORTANT SAFETY INSTRUCTIONS 

1.

 

Read these instructions.

 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do  not  block  any  ventilation  openings.  Install  in  accordance  with  the 

manufacturer’s 

instructions. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 
other apparatus (including amplifiers) that produce heat. 

 

Содержание eCA120

Страница 1: ...50 0285 0104 eCA120 EN eCA120 COMPACT AMPLIFIER Stereo Micro Amplifier USER MANUAL ...

Страница 2: ...ATION 7 6 1 Location and assembly 7 6 2 Mains connection 7 6 3 Audio input connections 8 6 4 Audio output connections 8 6 5 Remote control port 8 OPERATION AND USAGE 9 7 1 Start up 9 7 2 AUTO STANDBY Function 9 7 3 LED indicators 10 7 4 Setup jumpers 10 CLEANING 10 DIAGRAM and LIST OF FUNCTIONS 11 BLOCK DIAGRAM 12 CONFIGURATION DIAGRAM 12 TECHNICAL CHARACTERISTICS 13 ...

Страница 3: ...sk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outlet with a protective earthing connection IMPORTANT SAFETY INSTRUCTION...

Страница 4: ...done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of the unit 17 The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shal...

Страница 5: ...a 3 year warranty COMPLIANCE WITH INTERNATIONAL STANDARDS The eCA120 micro amplifier complies with the following international standards EN55103 1 Electromagnetic Compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emission EN55103 2 Electromagnetic Compatibility Product family standard for audio video audio vi...

Страница 6: ...x 60 W RMS 4 amplifier Universal external power supply AUTO STANDBY function in the absence of an audio signal the unit automatically goes into STANDBY mode minimising power consumption Lightweight silent high performance amplifier fan free convection cooling Suitable for stereo and parallel mono 1 unbalanced stereo line input LINE IN STACK with dual RCA connector and 3 pin Euroblock connector Loc...

Страница 7: ...ble shelf cupboard etc thanks to its design and layout of its connectors controls and LED indicator lights 6 2 Mains connection The amplifier is powered by alternating current through its external power source 100 240 VAC and 50 60 Hz This apparatus must be earthed through its mains cable earth resistance Rg 30 or lower The atmosphere should be as dry and dust free as possible Do not expose the un...

Страница 8: ...ecause none of the inputs have an RIAA preamp 6 4 Audio output connections The amplified output OUT L and R have Euroblock connectors The connection cable that connects the eCA120 connectors and the speakers should be good quality with a suitable cross section and as short as possible The L and R outputs respectively deliver an amplified version of the L and R inputs of the unit Remember that the ...

Страница 9: ...on mode means you can install the eCA120 in inaccessible places and leave the device connected to the mains power supply permanently because when no signal is detected it automatically goes into standby mode saving energy To enable the AUTO STANDBY mode the jumper labeled AUTO STBY on the front panel has to be in the ON position When it is enabled and after 2 minutes or more without any audio sign...

Страница 10: ...al a few seconds the amplifier may go into protection mode being muted to return to normal operation in a short time ON STBY the green light comes on when the equipment is in normal operating mode and it goes orange when it is in standby or low consumption mode STANDBY 7 4 Setup jumpers REMOTE REMOTE enables ON the remote volume control from a WPm type wall panel or another model of the WPm series...

Страница 11: ...by indicator light 2 DC24V power connector 3 CLIP indicator light 4 OUT L R amplified output 5 SP input signal presence indicator light 6 VOLUME knob 7 Euroblock input line LINE 8 RCA input line LINE1 9 RJ 45 REMOTE connector 10 REMOTE AUTO STANDBY jumpers ...

Страница 12: ...12 BLOCK DIAGRAM CONFIGURATION DIAGRAM REMOTE OFF AUTO STANDBY ON JUMPERS FACTORY ADJUST REMOTE AUTO STANDBY J105 J107 J106 J104 off off on on ...

Страница 13: ... VOLUME at 0dB Volume adjust to 6dBV Signal Noise Ratio 85dB VOLUME at 0dB Remote control externally selectable Master Volume Analog 0 10V based Auto standby Time 2 minutes aprox Threshold 40dBV L R DC supply 24V Mains using supplied DC adapter 100 240VAC External PSU 24VDC Power consumption pink noise 1 8 power 38VA 26W pink noise 1 3 power 61VA 51W Standby time 2 minutes 2 5W General Dimensions ...

Страница 14: ...ght to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on our website in Support Technical requests Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...

Отзывы: