ECKey EK6 series Скачать руководство пользователя страница 1

(

(

(

(

(

(

Inst

allation and Operation Guide

)

)

)

)

)

)

KEY

EC

CONVENIENT SECURITY.
YOUR PHONE IS YOUR KEY.

CONTENTS

1.

Installing ECKey Readers……………………………………………………………………………… 2

2.

Enrolling a User…………………………………………………………………………………………. 3

3.

Triggering the Reader…………………………………………………………………………………….. 3

4.

Bluetooth Modes and Hidden Phones…………………………………………………………………. 4

5.

PC Management Software……………………………………………………………………………… 4

6.

PC Management Software Settings…………….........………………………………………………… 5

7.

Configuring an EK6 Reader …………………………………………………………………………… 6

8.

Configuring an EK7 Reader…………………………………………………………………………… 11

9.

Troubleshooting ECKey Readers……………………………………………………………………… 12

10. Range Tuning…………………………………………………………………………………………….. 13

11.

Common ECKey Status Light Patterns………………………………………………………………… 14

12. Technical Specifications………………………………….……………………………………………… 15

This guide provides detailed information related to the installation and operation of ECKey EK6 and
EK7 readers. This guide is applicable to readers with firmware version 4.3.0 and the PC Management
Software v5.0. For guides and information on older versions of ECKey readers, firmware, and software
please contact [email protected].

1

Содержание EK6 series

Страница 1: ...ader 6 8 Configuring an EK7 Reader 11 9 Troubleshooting ECKey Readers 12 10 Range Tuning 13 11 Common ECKey Status Light Patterns 14 12 Technical Specifications 15 This guide provides detailed information related to the installation and operation of ECKey EK6 and EK7 readers This guide is applicable to readers with firmware version 4 3 0 and the PC Management Software v5 0 For guides and informati...

Страница 2: ...o the reader or phone Construction materials will affect read range so test the phones before commissioning the system When properly powered the reader should have a solid red status light If the reader has a purple status light on initial power up simply remove and reapply power 2 Red Black Tan Green White Orange Grey Purple Pink Yellow Blue Brown WIRE EK6 EK7 12 24V DC supply 24VAC DC ground 24 ...

Страница 3: ...ader should locate your phone Enter PIN when prompted default is 1234 status light blinks blue during registration solid blue when successful The reader will trigger once and status light will return to red Make phones discoverable one by one until all phones are paired After all phones have been paired press and release the Administration Button to reset the reader 3 Triggering the Reader Most tr...

Страница 4: ...nnecting the USB cable both connectors are keyed and must be aligned properly iv The status light should be red and drivers should be installing on the PC If the PC does not automatically install drivers they can usually be obtained through Windows Updates or can be manually downloaded from http www ECKey com download v Launch the PC Management Software At the ECKey Connection Window select the ra...

Страница 5: ...cific ECKey settings not necessarily all settings on the reader b ECKey i Get Settings See below under Toolbar Items section ii Apply Settings See below under Toolbar Items section iii Manual Pairing Places reader into discoverable mode allowing a phone to locate it and begin the manual pairing procedure iv Reset Settings Reset Will revert all reader settings back to factory defaults Users and aud...

Страница 6: ...e EK6 offers only Card Reader c Relay Type Defines the Wiegand output format that will be sent to the access control system on trigger d Buzzer Defines the on board buzzer duration when triggered by phone Options are i Silent no buzzer ii On with relay buzzer on for duration of triggered action iii On for period of 1 second momentary buzz when triggered e Site Code Site code for the 26 bit Wiegand...

Страница 7: ... checkbox is checked on the PIN Tab Oftentimes this does not need to be changed from the default but if the Passkey is changed here the Passkey must also be updated on the VIZpin Portal See the VIZpin Configuration Guide for details g Trigger Sensor The Trigger Sensor setting is referring to the optional device connected to the ECKey reader s pink wire Oftentimes this is a presence detector such a...

Страница 8: ...must enter the Manager PIN This is known as keypad mode k Pairing Defines how you enroll pair a phone with the reader See Enrolling a User section i Automatic The reader attempts to pair with any discoverable phone in range ii Manual default User must hold the administration button for 3 seconds to initiate pairing PIN Tab a PIN PIN used for enrollment triggering the reader on USER section PIN use...

Страница 9: ...0 35 being the shortest distance from the reader Double clicking on the Range value will allow you to adjust this device specific trigger range h PIN Static PIN for this phone i Card Number Wiegand Card Number associated with this phone EK6 Only j Refresh Updates User list with most recent information k Set Pairing Mode Makes the reader discoverable so that a user can locate and pair with it from ...

Страница 10: ...ith the reader s normal operation a Time Date and time of event b Name If event is related to a user the user s name will be displayed here c Address Bluetooth address of the associated user d Event The type of event that occurred e Detail Information about the event f Refresh Updates the Audit Trail to show all available events since last refresh g Clear Permanently purges the Audit Trail h Expor...

Страница 11: ...es how the relay operates when the EK7 is triggered dependent on Application selected above Options are i Unlock simulated button press Relay is activated for Open Pulse Length then deactivates and resumes searching for phones Set the Minimum Delay period to the time the door will be held open from this activation Reader will resume searching for phones after Min Delay period has passed ii Unlock ...

Страница 12: ...nlock open mode and ignore phones until the Admin Button is activated i Sensor If a position sensor is installed it will be used as follows i Door Lock Lock the door when sensor indicates door is closed ii Door Gate Opener Reader will not attempt to open close door if sensor indicates door is already in that state iii Door Gate Opener Reader will try to re open a door if sensor indicates it was no...

Страница 13: ...lues are from 35 100 The reader uses the RSSI and Range setting to estimate trigger range however there are many variables that will affect the RSSI and therefore may produce shifting results Ideally the Range setting under the Security Tab should be set to 55 and the phone should be paired at the longest required trigger distance In most cases this will ensure the paired signal strength and dista...

Страница 14: ...ing for phones but can be connected over Bluetooth for administration Blue Single Flash to Off ECKey requesting PIN from phone Single Flash to Red ECKey available to be discovered by phones for pairing Single Flash to Yellow ECKey requesting Manager PIN Double Flashes Phone has been paired and is now a Hidden device Triple Flashes ECKey available to be discovered for administration Quadruple Flash...

Страница 15: ... grams Operating Temperature 40 F 40 C to 185 F 85 C Inputs Sensors Status light control EK6 door sensor EK7 external trigger EK6 EK7 admin button EK6 EK7 Outputs Wiegand 26 or 48 bit EK6 or NC NO dry contact relay EK7 Relay 750mA 24v latching or pulse 0 1 to 60 secs EK7 Range 0 30 feet 0 10M Range Tuning Manual Automatic Device Specific User Limit Unlimited for non paired and VIZpin users 100 if ...