KGL Operating Manual – UA 412 S
2019-01-14
/
107 122
Single-zone operation or BT 300 operator interface
c
K = Cooling
d
A = Defrost
e
T = door (only for room controller)
f
W = Warning (alarm)
9.2.7 Menu 6 Configuration
KONFIGURAT POS: XXXXX
1 Refrigeration point
Continue to menu 6-1
2 Controller
Continue to menu 6-2
3 Cooling
Continue to menu 6-3
4 Language
Continue to menu 6-4
5 Alarm Priorities
Continue to menu 6-5
6 Emergency power operation
Continue to menu 6-6
Menu 6-1 - Refrigeration point
KÜHLSTELLE POS:
XXXXX
Input
Default
Refr. Pt. Name:
Only text
xxxxxxxxxxxxxxx
Free text that designated the refrigeration point (see note after the table)
Case
controller
Position: XXXXX
Free text that is displayed in the menu after position (POS) (see note after the
table)
UA400
Priority: XX
Priority of the alarms for refrigeration point failure or setting of the global controller
priority (menu 6-5)
,
, or numbers
(0..99)
1
Fühleranzahl XX
Display of the connected temperature sensors
After input of
, a sensor scan is performed, during which the number of sensors
is determined again.
The priority for older versions of the store computer (<V5.0) may only be allocated in the range 0..2;
.
see
Alarm signalling and monitoring, page 114
A meaningful name should be entered which provides details about the position of the sensor, e.g.
Cheese Counter 2 and KT2. The input is made using the menus of the system centre / store
computer / operator terminal. Direct input using the menus of the case controller shown in the
operator terminal is not possible. It is also not possible to make the entry using the BT 300 operator
interface.
Menu 6-2 - Controller
REGLER POS: XXXXX
1 Type and version
Continue to menu 6-2-1