19 / 97
Introduction Manual ENC66
eckelmann.de
1.4.5
The LEDs in normal operation
The state of the single LED in normal operation is described in the respective chapters of /
A/. The following table gives an overview:
Tabelle 11:.
Table 11:
LEDs in normal operation, ENC66
LED
Indication
Meaning
WDOG
On:
Off:
Watchdog ok
Error: Watchdog is de-energized
CAN1/LED1
Flashing light:
Flashing at 2 Hz:
RX-Status ok
RX-Error-Counter>13
CAN1/LED2
Flashing light:
Flashing at 2 Hz:
TX-Status ok
TX-Error-Counter>13
CAN2 to CAN4
yellow
Flashing light:
Flashing at 2 Hz:
TX-Status ok
TX-Error-Counter>13
CAN2 to CAN4
green
Flashing light:
Flashing at 2 Hz:
RX-Status ok
RX-Error-Counter>13
CAN2 to CAN4
green and yellow
synchronous
Synchronous flashing at 1 Hz:
Synchronous flashing at 0,5 Hz
State error passive
State bus-off
RS232/yellow
Flashing light:
Transmitting of data (TX-Status)
RS232/green
Flashing light:
Receiving of data (RX-Status)
ETHERNET/yellow
Flashing light:
signals data transfer via RX or TX
ETHERNET/green
Off:
On:
no ethernet connection available
as soon as an ethernet connection is estab-
lished (result of the internal link integrity
test)
Содержание E-Control CNC
Страница 92: ...92 97 Abbildung 66 Figure 66 Controller error message in the StdHMI ...
Страница 96: ...96 97 ...