PE-225
MAINTENANCE
X7732272804
27
© 03/21 ECHO Incorporated
Maintenance Intervals
IMPORTANT NOTE
- Time intervals shown are maximum. Actual use and
your experience will determine the frequency of required maintenance.
MAINTENANCE PROCEDURE NOTES:
1
Apply lithium based grease every 25 hours of use.
2
Apply lithium based grease every 50 hours of use.
3
Low evaporative fuel tanks DO NOT require regular maintenance to
maintain emission integrity.
* Replacement is recommended based on the finding of damage or wear
during inspection.
COMPONENT / SYSTEM
MAINTENANCE
PROCEDURE
SKILL
LEVEL
Daily or Before Use
Air Filter
Inspect / Clean*
1
Choke Shutter
Fuel System
Inspect
3
Cooling System
Inspect / Clean
2
Recoil Starter Rope
Inspect / Clean*
1
Screws / Nuts / Bolts
Inspect / Tighten / Replace*
Blade
Inspect / Replace*
1
Every Refuel
Fuel System
Inspect
3
1
3 Months
Air Filter
Replace*
1
Fuel Filter
Inspect*
Fuel Cap Gasket
Spark Plug
Inspect / Clean / Replace*
Muffler Spark Arrestor
2
Cylinder Exhaust Port
Inspect / Clean / De-carbon
Drive Shaft (flex cable models)
Grease
1
Gear Housing (some models)
Grease
2
Yearly
Fuel Filter
Inspect / Replace*
1
Fuel Cap Gasket
Replace*