2.
Purge Bulb
Pump purge bulb (C) until fuel is
visible. Pump bulb an additional
4 or 5 times.
3.
Recoil Starter
Pull recoil starter handle (D) and
engine should start. Do not use
choke (B)
Note: If engine does not start
after 5 pulls, use cold
start procedures.
Stopping Engine
- PB-580 H
1.
Throttle Lever
Move throttle lever (A) to IDLE
position and allow engine to
return to idle before shutting off
engine.
2.
Throttle Lever
Move throttle lever (A) to “
O
“
(STOP) position.
- PB-580 T
1.
Throttle Lever
Release throttle trigger. Move Throttle Lever (A) forward to idle position
and allow engine to return to idle before shutting off engine.
2.
Throttle Lever
Move Throttle Lever (A) all the way forward to STOP position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.