background image

11

P

OWER

 B

LOWER

O

PERATOR

'

S

 M

ANUAL

P

RE

-O

PERATION

FUEL

Fuel Requirements

Gasoline - Use 89 Octane [R+M/2] (mid grade or higher) gasoline known
to be good quality. Gasoline may contain up to 15% MTBE (methyl
tertiary-butyl ether). Gasohol containing methyl (wood) alcohol is NOT
approved.

Two Stroke Oil - A two-stroke engine oil meeting ISO-L-EGD (ISO/CD
13738) and J.A.S.O. FC Standards must be used. Echo brand premium
Power Blend 

TM

 Universal 2-Stroke Oil meets these standards. Engine

problems due to inadequate lubrication caused by failure to use an ISO-
L-EGD and J.A.S.O. FC certified oil, such as Echo premium Power Blend

TM

, will void the two-stroke engine warranty.  (Emission related parts

only are covered for two years, regardless of two-stroke oil used, per
the statement listed in the Emission Defect Warranty Explanation.)

IMPORTANT
Echo premium Power Blend 

TM

 Universal 2-Stroke Oil may be mixed

at 50:1 ratio for application in all Echo engines sold in the past
regardless of ratio specified in those manuals.

Mixing Instructions

1.

Fill an approved fuel container with half of the required amount of
gasoline.

2.

Add the proper amount of 2-stroke oil to gasoline.

3.

Close container and shake to mix oil with gasoline.

4.

Add remaining gasoline and remix.

5.

Install fuel container cap and wipe any spilled fuel from container
and surrounding area.

Handling Fuel

WARNING  

  DANGER

Fuel is VERY flammable. Use extreme care when mixing, storing or
handling or serious personal injury may result.
• Use an approved fuel container.
• DO NOT smoke near fuel.
• DO NOT allow flames or sparks near fuel.
• Fuel tanks/cans may be under pressure. Always loosen fuel caps

slowly allowing pressure to equalize.

• NEVER refuel a unit when the engine is HOT!
• NEVER refuel a unit with the engine running.
• DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks outdoors

over bare ground.

• Securely tighten fuel cap after refueling.
• Inspect for fuel leakage. If fuel leakage is found, do not start or

operate unit until leakage is repaired.

IMPORTANT
Spilled fuel is a leading cause of
hydrocarbon emissions. Some states
may require the use of automatic fuel
shut-off containers to reduce fuel
spillage. Contact your ECHO dealer
for ordering information.

After Refueling -
• Wipe any spilled fuel from the unit.
• Move at least 3 m (10 ft.) from refueling

location before starting.

After use -
• DO NOT store a unit with fuel in its tank.

Leaks can occur. Return unused fuel to an
approved fuel storage container.

Storage -
Fuel storage laws vary by  locality. Contact
your local government for the laws affecting
your area. As a precaution, store fuel in an
approved, air tight container. Store in a well
ventilated, unoccupied building, away from
sparks and flames. Do not store fuel longer
than 30 days.

IMPORTANT
Stored fuel ages. Do not mix more fuel
than you expect to use in thirty (30)
days, ninety (90) days when a fuel
stabilizer is added.

Stored two-stroke fuel may separate.
ALWAYS shake fuel container thor-
oughly before each use.

Содержание PB-460LN

Страница 1: ...operationandallinstructionscarefully ECHOprovidesthis Operator sManualwhichmustbereadandunderstoodforproperandsafeoperation X750006700 12 03 X7501128900 Power Blower Operator s Manual MODEL PB 460LN S...

Страница 2: ...Customer Assistance 24 Warranty Card 24 Additional or Replacement Manuals 24 Manual Ordering Instructions 24 Specifications descriptions and illustrative material in this literature are as accurate as...

Страница 3: ...ver is shown within the circle is prohibited IMPORTANT Theenclosedmes sage provides information necessary for the protection of the unit NOTE This enclosed message provides tips for use care and maint...

Страница 4: ...ection whenever unit is used Proper Clothing Wear snug fitting durable clothing Pants should have long legs shirts with long sleeves DONOTWEARSHORTS DONOTWEARTIES SCARVES JEWELRY Wear sturdy work shoe...

Страница 5: ...nds arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those areas Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress In...

Страница 6: ...conditions into account avoid open doors and windows Do not point blower at people or animals Start unit on ground with throttle at idle Check that blower pipe is not blocked by the ground or by any o...

Страница 7: ...withSwivel __ 1 StraightPipe __ 1 CurvedPipe __ 1 Operator s Manual __ 1 Warranty Registration Card __ 1 ECHO Emissions and Warranty Statement __ 2 Clampsw screws __ 1 Stick Handle Assembly __ 1 Echo...

Страница 8: ...he clear fuel tank return line Pump bulb an additional 4 or 5 times 6 CHOKE Move lever up to Cold Start starting position and for emergency stopping Move lever down to Run position 7 FUELTANKCAP Cover...

Страница 9: ...ExhaustSystem Spark Arrestor Muffler w Catalyst Fuel Mixed GasolineandTwo strokeOil Fuel OilRatio 50 1 two stroke air cooled engine oil Gasoline 89 Octane unleaded DO NOT use fuel containing methyl al...

Страница 10: ...may be used to ease assembly of flexible pipe to blowerelbow 4 Loosen wing nut E completely and expand stick handle clamp F 5 Align notches G in handle clamp with pipe pegs H Stick handle should be an...

Страница 11: ...Useextremecarewhenmixing storingor handling or serious personal injury may result Use an approved fuel container DONOTsmokenearfuel DO NOT allow flames or sparks near fuel Fuel tanks cans may be under...

Страница 12: ...o IDLE DETENT position 2 Choke Move choke B up to Cold Start position 3 Primer Bulb Pump primer bulb C until fuel is visible and flows freely in the clear fuel tank return line Pump bulb an additional...

Страница 13: ...D and engine should start Do not use choke B NOTE If engine does not start after 5 pulls use cold start procedures STOPPING ENGINE 1 Throttle Lever Move throttle lever A to idle detent position and a...

Страница 14: ...e to warm up at a fast idle for a few minutes 4 Set engine speed with throttle A 5 Use lower speed to blow dry grass and leaves from walks patios and drives 6 Additional speed may be necessary to clea...

Страница 15: ...2 R O S R U O H Y L R A E Y s e r u d e c o r P e c n a n e t n i a M r e l a e D o h c E d e d n e m m o c e R t r o P t s u a h x E r e d n i l y C n o b r a c e D n a e l C t c e p s n I 3 C I s e...

Страница 16: ...he cavity in the air cleaner cover is installed with the original side out 4 Wash silencer in suitable solvent such as dish washing solution 5 Dry silencer before reinstalling FUEL FILTER Level1 Tools...

Страница 17: ...ols required 25 50mm 1 2 in cleaning brush cross head screwdriver Parts Required None if you are careful IMPORTANT To maintain proper engine operating temperatures cooling air mustpass freely through...

Страница 18: ...engine output and overheating Spark arrestor screen must be checked periodically 1 Remove spark plug and engine covers five screws 1 Remove spark plug and engine cover five screws IMPORTANT Exact plac...

Страница 19: ...n CW until the engine does not hesitate on acceleration For engine operation below 2 000 feet turn the high speed needle rich CCW until the engine runs between 6 200 and 7 200 RPM Then turn the low sp...

Страница 20: ...ew just touches throttle plate then turn three 3 turns clockwise Final Adjustment IMPORTANT Limiter caps prevent exceeding emission limits and over rich adjustment but not over lean adjustment which c...

Страница 21: ...v o C l e u f h t i w d e l u o F e v i t c e f e d g u l P n i 6 2 0 0 m m 5 6 o t t s u j d A e c a l p e r r o n a e l C e c a l p e r r o n a e l C g u l p e c a l p e R s n u r e n i g n E r o s...

Страница 22: ...accumulation of grease oil dirt and debris fromexteriorofunit 4 Perform all periodic lubrication and services that are required 5 Tighten all screws and nuts 6 Drain the fuel tank completely and pull...

Страница 23: ...23 POWER BLOWER OPERATOR S MANUAL NOTES...

Страница 24: ...CHO ConsumerProductSupportDepartmentat1 800 673 1558from8 30am to 4 30 pm Central Standard Time Monday through Friday Before calling please know the model and serial number of your unit to help your C...

Отзывы: