manualshive.com logo in svg
background image

Power  Blower

Operator's Manual

MODELS:

PB-650

Serial Number 04001001 - 04002000

WARNING  

  DANGER

Read rules for safe operation and all instructions carefully.  ECHO provides this
Operator's Manual which must be read and understood for proper and safe operation.

X750003020
06/01

X7501126900

Содержание PB-403

Страница 1: ...MODELS PB 650 Serial Number 04001001 04002000 WARNING DANGER Readrulesforsafeoperationandallinstructionscarefully ECHOprovidesthis Operator sManualwhichmustbereadandunderstoodforproperandsafeoperatio...

Страница 2: ......

Страница 3: ...l find safety alerts and helpful information messages preceded by symbols or key words The following is an explanation of those symbols and key words and what they mean to you This symbol accompanied...

Страница 4: ...l Condition Your judgment and physical dexterity may not be good if you are tired or sick if you are taking medication if you have taken alcohol or drugs Operate unit only if you are physically and me...

Страница 5: ...me pain in those areas Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress Injury RSI AnextremeRSIconditionisCarpalTunnelSyndrome CTS which could occur whe...

Страница 6: ...perations Use only during appropriate hours Never use a higher speed setting then necessary to perform a task The higher the engine speed the louder the blower noise Be a good neighbor AvoidHotSurface...

Страница 7: ...hot glowing particles of carbon from leaving the muffler Keep exhaust area clear of flammable debris 3 RECOILSTARTERHANDLE Pullrecoilhandleslowlyuntilstarterengages thenquicklyandfirmly When engine s...

Страница 8: ...b l a W m e t s y S n o i t i n g I e p y t n o i t i n g i e g r a h c s i d r o t i c a p a c o t e n g a M l e e h w y l F g u l P k r a p S n i 6 2 0 0 m m 5 6 0 p a G Y 8 R M P B K G N m e t s y...

Страница 9: ...pipe B and tighten 4 Loosen wing nut E completely and expand open stick handle clamp F 5 Align notches G in handle clamp with pipe pegs H Stick handle should be angled away from operator 6 Slide stic...

Страница 10: ...rious personal injury may result Use an approved fuel container DONOTsmokenearfuel DO NOT allow flames or sparks near fuel Fuel tanks cans may be under pressure Always loosen fuel caps slowly allowing...

Страница 11: ...imerBulb Prime Pump primer bulb D until fuel is visible and flows freely in the clear fuel tank return line Pump bulb an additional 4 or 5 times 4 Pull recoil starter handle D until engine fires 5 or...

Страница 12: ...and 6 carefully IMPORTANT To avoid engine damage due to over revving do not block blower pipe opening 1 Use only during appropriate hours 2 Allow the engine to warm up at a fast idle for a few minute...

Страница 13: ...O H 6 S H T N O M 0 7 2 R O S R U O H Y L R A E Y s e r u d e c o r P e c n a n e t n i a M r e l a e D o h c E d e d n e m m o c e R t r o P t s u a h x E r e d n i l y C n o b r a c e D n a e l C t...

Страница 14: ...element can be cleaned and reused be certain it still fits the cavity in the air cleaner cover is installed with the original side out FUEL FILTER Level1 Tools required Fuel line hook 203 254mm 8 10 i...

Страница 15: ...f cooling passage blockages or cleaning of cooling fins is considered Normal Maintenance Any failure attributed to lack of maintenance is not warranted Cleaning Grill 1 Remove accumulated debris from...

Страница 16: ...ked periodically 1 Remove spark plug and engine cover four screws 2 Remove spark arrestor cover A and spark arrestor screen B from muffler Replace screen if plugged with carbon deposits 3 Install spar...

Страница 17: ...E Do not adjust carburetor unless necessary If you have difficultly see your ECHO dealer BeforeAdjustment Check that Air filter is clean and properly installed Spark arrestor screen is free of carbon...

Страница 18: ...gap incorrect Covered with carbon Fouled with fuel Spark plug defective Adjust 0 65mm 0 026in Clean or replace Clean or replace Replace plug Engine does not crank Internal engine problem See your ECH...

Страница 19: ...personal injury may result Long Term Storage Over 30 Days Do not store your unit for a prolonged period of time 30 days or longer without performing protective storage mainte nance which includes the...

Страница 20: ...maintenance of this product you may call the ECHO ConsumerProductSupportDepartmentat1 800 673 1558from8 30am to 4 30 pm Central Standard Time Monday through Friday Before calling please know the model...

Страница 21: ...SEMBLY INSTALL BLOWER PIPES STICK HANDLE PAGE 9 1 Assemble clamps A onto both ends of flexible pipe B 2 Assemble straight pipe with swivel C into flexible pipe B 3 Assemble flexible pipe B to elbow D...

Страница 22: ...se choke COLD START position to stall engine Have your ECHO dealer repair stop switch before using blower again A ECHO CONSUMER PRODUCT SUPPORT If you require assistance or have questions concerning t...

Страница 23: ...650 U S X750002810 X7501126600 PB 603 U S X750002230 X7501125300 PB 650 Can X750003020 X7501126900 Favor de notar este cambio Las abrazaderas que vienen con este modelo para el ensamble del tubo flexi...