background image

15

P

ower

 B

lower

 

o

Perator

'

s

 M

anual

Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help 

your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your 

unit to an ECHO Service Dealer for maintenance.  To help you decide whether you want to DO-IT-YOURSELF or have 

the ECHO Dealer do it, each maintenance task has been graded. If task is not listed, see your ECHO Dealer for repairs.

skIll

 

level

 

Level 1

 =  Easy to do. Common tools may be required.

 

Level 2

 =  Moderate difficulty. Some specialized tools may be required.

ECHO offers 

REPOWER

TM

 Maintenance Kits and Parts to make your maintenance job easier. 

m

aInTenanCe

  

 warning

Moving parts can amputate fingers or cause severe injuries.  Keep hands, clothing and loose objects away from all 

openings.  Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop 

before removing obstructions, clearing debris, or servicing unit. Allow unit to cool before performing service. Wear 

gloves to protect hands from sharp edges and hot surfaces.

maInTenanCe

 

InTervals

COMPONENT / SYSTEM

MAINTENANCE

PROCEDURE

REQ'D

SKILL

LEVEL

DAILY OR 

BEFORE USE 

EVERY

REFUEL

3 MONTHS 

OR 90 

HOURS

YEARLY

600 HOURS

Air Filter

Inspect/Clean

1

I / C *

R *

Choke Shutter

Inspect/Clean

1

I / C

Fuel Filter

Inspect/Replace

1

I  *

I / R *

Fuel Cap Gasket

Inspect/Replace

1

I  *

R *

Fuel System

Inspect/Replace

1

I (1) *

I (1) *

Spark Plug

Inspect/Clean/Replace

1

I / C / R *

Cooling System

Inspect/Clean

2

I / C

Muffler Spark Arrestor

Inspect/Clean/Replace

2

I / C / R *

Cylinder Exhaust Port

Inspect/Clean/Decarbon

2

I / C

Recoil Starter Rope

Inspect/Clean

1

I / C * 

Screws/Nuts/Bolts

Inspect/Tighten/Replace

1

I  *

MAINTENANCE PROCEDURE LETTER CODES:  I = INSPECT,   R = REPLACE,  C = CLEAN
IMPORTANT NOTE

 - Time intervals shown are maximum. Actual use and your experience will determine the 

frequency of required maintenance.

MAINTENANCE PROCEDURE NOTES:

(1) Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.
* All recommendations to replace are based on the finding of damage or wear during inspection.

Содержание PB-255

Страница 1: ...r s Manual MODEL PB 255 X753002695 01 10 X7531180205 warning Read rules for safe operation and instructions carefully ECHO provides this Operator s Manual which must be read and understood for proper...

Страница 2: ...l or Replacement Manuals 28 Specifications descriptions and illustrative material in this literature are as accurate as known at the time of publica tion but are subject to change without notice Illus...

Страница 3: ...y alert symbol accompanied by the word WARNING calls attention to an act or condi tion which CAN lead to serious personal injury or death if not avoided Circle and slash symbol This symbol means the s...

Страница 4: ...th cap or net Hot Humid Weather Heavy protective clothing can increase operator fatigue which may lead to heat stroke Schedule heavy work for early morning or late afternoon hours when temperatures ar...

Страница 5: ...r operation Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in t...

Страница 6: ...mplete stop before removing obstructions clearing debris or servicing unit DO NOT start or operate unit unless all guards and protective covers are properly assembled to unit NEVER reach into any open...

Страница 7: ...l cannot be read a new one can be ordered from your ECHO dealer See PARTS ORDERING instructions for specific information 1 2 4 6 7 9 10 3 8 11 12 13 P N X505002310 P N X505002080 Hot Decal near muffle...

Страница 8: ...8 Spark arrestor muffler or spark arrestor muffler with catalyst The muffler or catalytic muffler controls exhaust noise and emission The spark arrestor screen prevents hot glowing particles of carbo...

Страница 9: ...fter inserting main blower pipe into fan case so that line F meets locking ring C rotate locking ring clockwise 1 8 turn to lock mian blower pipe in place 5 Align groove H in fan head pipe with tabs G...

Страница 10: ...ase locking ring C with a coin or screwdriver and rotate ring so that lock symbol A is at top of ring 2 Remove pipes from locking ring Operation WARNING Moving parts can amputate fingers or cause seve...

Страница 11: ...T store a unit with fuel in its tank Leaks can occur Return unused fuel to an approved fuel storage container Storage Fuel storage laws vary by locality Contact your local gov ernment for the laws aff...

Страница 12: ...o not allow the rope to snap back in Always hold the unit firmly 5 Recoil Starter Place the unit on a flat clear area Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle r...

Страница 13: ...ll recoil starter handle rope E until en gine fires IMPORTANT Recoil starter Use short pulls only 1 2 2 3 of rope for start ing Do not allow the rope to snap back in Always hold the unit firmly NOTE I...

Страница 14: ...l handle with left hand and lower handle stand with right hand operating blower WARNING Engine exhaust IS HOT and contains Carbon Monoxide CO a poison gas Breathing CO can cause unconsciousness seriou...

Страница 15: ...obstructions clearing debris or servicing unit Allow unit to cool before performing service Wear gloves to protect hands from sharp edges and hot surfaces maintenance intervals COMPONENT SYSTEM MAINT...

Страница 16: ...stall the new filter air filter Level 1 Tools required 25 50 mm 1 2 in Cleaning brush Parts required REPOWERTM AIR FUEL FILTER KIT NOTE Clean daily 1 Close choke Cold Start Position This prevents dirt...

Страница 17: ...mal Maintenance Any failure attributed to lack of maintenance is not warranted Cleaning Grill 1 Brush accumulated debris from crankcase intake grill above the fuel tank Cleaning Cylinder Fins 1 Remove...

Страница 18: ...d attach spark plug lead 5 Tighten all screws securely Exhaust Port Cleaning Level 2 Tools required Wood or plastic scraper 4 mm Hex Wrench Parts Required As needed Heat Shield 1 Remove spark plug lea...

Страница 19: ...usted when operating the engine below 1 100 feet ASL otherwise severe engine damage may result Level 2 Tools required Screwdriver tachometer Echo P N 99051130017 Parts required None NOTE Every unit is...

Страница 20: ...e r e v o C l e u f h t i w d e l u o F e v i t c e f e d g u l P n i 6 2 0 0 m m 5 6 o t t s u j d A e c a l p e r r o n a e l C e c a l p e r r o n a e l C g u l p e c a l p e R s n u r e n i g n E...

Страница 21: ...Place the stop switchs in the STOP position 3 Remove accumulation of grease oil dirt and debris from exterior of unit 4 Perform all periodic lubrication and services that are required 5 Tighten all sc...

Страница 22: ...r with catalyst Fuel Mixed Gasoline and Two stroke Oil Fuel Oil Ratio 50 1 Power Blend X ISO L EGD ISO CD 13738 and J A S O M345 FC FD two stroke air cooled engine oil Gasoline Use 89 Octane unleaded...

Страница 23: ...ntial or non income producing use will be covered by this limited warranty for five 5 years from date of purchase EXCEPTIONS For two stroke engine powered products the electronic ignition module flexi...

Страница 24: ...e procedures stale fuel including failure to provide or perform required maintenance services as prescribed in the operator s manual Preventative maintenance as outlined in the operators manual is the...

Страница 25: ...t SORE was designed built and equipped to conform with applicable EPA and C A R B emissions standards and that your equipment SORE is free from defects in material and workmanship that would cause it...

Страница 26: ...26 notes...

Страница 27: ...27 Power Blower Operator s Manual notes...

Страница 28: ...presenting your unit for Warranty service repairs proof of purchase is required echo consumer product support If you require assistance or have questions concerning the applica tion operation or maint...

Отзывы: