NOTICE
• Do not overload. The total load of all electrical appliances must
not exceed the supply range of the generator. Overloading will
damage the generator.
• When supplying precision equipment, electronic controllers,
PCs, Electronic computers, microcomputer based equipment or
battery chargers, keep the generator a sufficient distance away to
prevent electrical interference from the engine. Also ensure that
electrical noise from the engine does not interfere with any other
electrical devices located near the generator.
• If the generator is to supply power to medical equipment, advice
should first be obtained from the manufacturer or a medical
professional.
• Some electrical appliances or general-purpose electric motors
have high starting currents, and cannot therefore be used, even if
they lie within the supply ranges given in the above table. Consult
the equipment manufacturer for further advice.
MAINTENACE
The engine must be properly maintained to ensure its operation is
safe, economical, and free of issues.
Maintenance, replacement, or repair of emission control devices and
systems may be performed by any engine repair establishment or
individual, using parts that are ‘’certified’’ to EPA standards.
In order to keep your gasoline engine in good working condition, it
must be periodically serviced. The following maintenance schedule
and routine inspection procedures must be carefully followed:
Items
Frequency
Each time
First month
or first
20hrs of
operation
Thereafter,
every 3
months or
every 50hrs
of operation
Every year
or every
100hrs of
operation
Engine oil
Check-Refill
X
Replace
X
X
Reduction gear
oil (if equipped)
Oil level check
X
Replace
X
X