26
Storage
PREPARATION FOR STORAGE
The following procedures should be followed prior to storage of your
generator for periods of 6 months or longer.
1. Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making
engine starting difficult. Add fuel stabilizer to fuel tank.
2. Remove the drain screw of the carburetor.
3. Change engine oil.
4. Check for loose bolts and screws, tighten them if necessary.
5. Clean generator thoroughly with clean cloth. NEVER USE WATER
TO CLEAN GENERATOR.
6. Pull recoil starter handle until resistance is felt, leaving handle in
that position.
7. Store generator in a well ventilated, low humidity area.
Generator Specifications
STORAGE
Engine Model
R210
Start
Manual
Rated Frequency
60Hz
Rated Voltage
120V
Rated Power
2.8KW
Fuel Tank Capacity
15L
Full Load Continuum Running Time
7h
50% Load Continuum Running Time
10h
Noise (7m)
72dB
Specifications for the Panel
2 x GFCI Duplex with water
proof cover, 1 x 120V- 30A
Twist lock-3 prongs with
water proof cover, Low oil
indicator
Certification
CSA/EPA/CARB
LOW THD
N/A
Wheels & Kits
Yes
Содержание EG-3500
Страница 34: ...34 NOTES ...
Страница 35: ...35 NOTES ...
Страница 70: ...34 NOTER ...
Страница 71: ...35 NOTER ...
Страница 106: ...34 NOTAS ...
Страница 107: ...35 NOTAS ...