HIGH PRESSURE PUMP REPAIR INSTRUCTION 

SERIES EP-12-34 / EP-14-34 / EP-17-34 

 

Disassembly sequence of the front end of the ECH

2

O Tec. high-pressure pump. 

Refer to the pump diagram. 

 

1) 

Remove the three discharge valve plugs and the three inlet valve plugs (32), with a 22 mm socket 

wrench.  Inspect the O-ring (33) for wear and replace if damaged. 

 
2) 

With  needle  nose  pliers,  remove  the  inlet  and  discharge  valve  assemblies  (32X).    Insert  a  small 

screwdriver  between  the  valve  seat  (27)  and  the  valve  spring  retainer  (30)  to  separate  the  valve 
assembly.  Remove the O-ring (31).  Inspect all parts for wear and replace if necessary. 

 
3) 

Next, use a 5 mm Allen wrench to remove the 8 socket head cap screws (34).  Carefully slide the 

valve casing (26) out over the plungers.  Remove the weep return ring (25), pressure ring (24) and 
V-sleeve with support ring (23), from the valve casing (26). Remove the V-sleeve (23) from the seal 
case (20).  Inspect all parts, including O-ring (21) for wear and replace if necessary. 

 
4) 

Check  surfaces  of  plunger  (16).    A  damaged  surface  will  cause  accelerated  wear  on  the  seals.  

Deposits of any kind must be carefully removed from the plunger surface.  

 

A damaged plunger must be replaced! 

 
5) 

If the ceramic plunger (16B) is damaged, remove the plunger bolt (16C).  Discard the old plunger 

(16B) and copper gasket (16D) and clean the old Locktite from the plunger bolt (16C) and plunger 
base (16A).  Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 
inch-pounds. 

 

NOTE: If there are deposits of any kind (i.e., lime deposits) in the valve casing, be certain that the 
weep holes in the weep return ring and valve casing have not been plugged. 
 

6) 

If the crankcase oil seals (19) are to be replaced, they can be removed by prying loose.  Take care 

not to make contact with the plunger.  If the oil seals are not to be replaced, proceed to the back end 
disassembly sequence and carefully pry the seals loose after the plungers have been removed from 
the crankcase.  

 

Disassembly sequence of the back end of the ECHO Tec. high-pressure pump. 
 

1) 

Before beginning, drain the oil from the crankcase, through the oil drain (3A). 

 
2) 

Remove the crankcase cover (3) and O-ring (4) from the crankcase (1).  To remove the crankshaft 

(13), remove the bearing cover (7) and sight glass (8).  Using a rubber mallet, remove the crankshaft 
axially through the connecting rods by tapping on the end of the shaft.  Do not bend or damage the 
connecting rods during crankshaft removal. 

 
3) 

Next remove the remaining bearing and radial shaft seal (11).  Inspect both bearings and seal for 

wear and replace if necessary. 

4) 

Remove the connecting rod (15), then the plunger (16) and wrist pin (17), if necessary.  Check the 

plunger bore in the crankcase for wear.  Inspect parts and replace as necessary. 

Содержание Watermakers 500-PRO-1

Страница 1: ...FEATURES 5 INSTALLATION INSTRUCTIONS 6 7 OPERATION INSTRUCTIONS 8 MEMBRANE CLEANING PROCEDURE 9 MAINTENANCE TIMETABLE 10 PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE 11 ELECTRICAL DIAGRAM 12 TROUBLESHO...

Страница 2: ...new ECHO Tec desalination system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose problems when they first develop Such proble...

Страница 3: ...jection TFC Polyamide thin film composite spiral wound single pass reverse osmosis element Salt Rejection min 99 5 Salinity Range System 500 900 up to 50 000 ppm TDS NaCl 1200 up to 40 000 ppm TDS NaC...

Страница 4: ...els and 5 and 20 micron cartridge filtration system 2 1 Fresh water flush kit with hose and 316SS hose clamps 3 1 Product water tube 10ft 3m 1 Reject hose 10ft 3m with 2pcs 316SS hose clamps 1 Intake...

Страница 5: ...e feed pump with the intake of the desalination system located at the pre filter assembly Secure all hoses with the supplied hose clamps PRODUCT WATER TUBING Connect the product water outlet marked SA...

Страница 6: ...changes set the selector switch on the electrical control panel to the FEED position feed pump only and purge the system until all entrapped air has escaped 6 In the AUTO position press the START but...

Страница 7: ...he seawater shut off valve and the seacock MEMBRANE STORAGE PROCEDURE If you intend to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance Th...

Страница 8: ...al scale remover See warning label on side of container and observe all safety precautions on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals tog...

Страница 9: ...and clean intake 1000 hrs or when clogged Pre filters Replace or clean elements and clean housings When system intake pressure drops below 5psi Charcoal flush filter Replace element Every 6 months Hig...

Страница 10: ...s inner wall and remove it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel o...

Страница 11: ...TRANS FORMER START SWITCH S1 PUSH BUTTON NO SELECTOR SWITCH S2 3 POSITION MAINT 4 CONTACTS NO T1 HIGH PRESS SWITCH S4 NC LOW PRESS SWITCH S5 NO TANK FULL SWITCH S6 NC EXTERNAL MAIN IN ELECTRICAL DIAG...

Страница 12: ...ns Check strainer and filter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suction leaks Open valve chamb...

Страница 13: ...16B and copper gasket 16D and clean the old Locktite from the plunger bolt 16C and plunger base 16A Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 inch pounds NOT...

Страница 14: ...s 12A and 12B if they were removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase Replace radial shaft seal 11 bearing cover with...

Страница 15: ......

Страница 16: ...ned to Echo Marine s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not exten...

Страница 17: ...ranteed against iron fouling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine ge...

Отзывы: