L I Q U I D C R Y S T A L D I S P L A Y
Section 5. Liquid Cr ystal Display
Understanding the LCD
Reading the liquid crystal display Modes, Position, Address’ and status
Note: LCD contrast is set via POT located to the upper left of LCD. (POT 2.)
LCD Status Line
LCD Position & Direction
The lift position is shown in the top left of the LCD display, followed by the
current demand direction.
The left side example shows the lift on the 2
nd
floor with an up direction
LCD Modes
The lift modes are shown in the top left centre of the LCD display.
The left side example shows the lift on Normal
•
CFS Lift on Car Fire Service
•
DDO Door Open Disable
(Toggle switch provided on board)
•
EP Lift on Emergency Power
•
EQK Earthquake input activated
•
HCB Hall Call Bypass
•
HFA Lift on Hall Fire Alternate Service
(USA-Fire Service Code 17.1 only)
•
HFS Lift on Hall Fire Service
•
IND Lift on Independent Service
•
INS
Lift on Inspection Service
(Toggle switch provided on board)
•
NOR Lift on Normal
•
NPT No Pulse Time out
(Fatal error. See Section 6,Counting method 01, NPT )
•
PRK Lift on Parking
•
ZON Lift zoned/zoning to floor
Section
5
02u
NOR IDL ][][
ECD Aust. V-4.02
02d
NOR
RDN ][][
ECD Aust. V-4.02