Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
6
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELP DESK
AT WWW.ECCOTEMP.COM FOR ALL OF OUR PRODUCT MANUALS.
INSTALLATION GUIDELINE
NOTE: The installation must be in compliance with the National Electrical Code, your local electrical and plumbing
codes.
1.
DO NOT install water heater near tinder, volatile or flammable substances, or near a strong magnetic field.
The unit must only be mounted in a VERTICAL position near the water fittings.
2. Do not install the unit in a room where there is a chance of freezing.
3.
Mount the unit to a flat section of wall, well away from any potential water splashes or spray. Be sure to
use wall anchors, or screw directly into studs.
4. Position the unit upright with all plumbing connections at the bottom of the unit.
1.
Make sure the appliance is intact, and all fittings are complete.
2. Please make sure the main power supply, water pressure, grounding condition, amp meter and wire meet all
standards of installation requirement.
3.
The water heater must be connected to a properly-grounded, dedicated branch circuit with the proper voltage
rating. The ground must be connected to the “ground bar” at the circuit breaker panel.
4.
This water heater
MUST
be permanently connected to fixed and dedicated circuit breakers. If the heater will
be unused, switch off the circuit breakers.
5.
When installing new unit please connect water fittings and turn water on so water flows through unit before
turning
POWER ON
PRODUCT INNER STRUCTURE CONTINUES...
MODEL iE-21 iE-24 iE-27
Display screen
Temp.sensor
bottom case
control board
Display screen
flowmeter
heating chamber
Terminal blocks
10.9 in.
17
.3 in.