eccola H-MAN X 2 Скачать руководство пользователя страница 1

 

Operating instruction  04_2022 

Page 1 

Service Address: 

eccola GmbH

  -  Im Alber 8 -  D-73084 Salach  -  Phone.:0049-7162-948996 

Internet: 

www.eccola.de

  email: [email protected] 

 

User Guide H-MAN X 2 

 

Congratulations 

H-MAN X 2 der Schnellhörtester.  

You have chosen the H-MAN X 2.  

We thank you for the confidence shown to us and wish you a successful use of the  
H-MAN

2

 for many years. 

 
Warranty 

Warranty 1 year.

  Any faults/ defects arising during the warranty period will be repaired free of charge. 

In case of any technical defect we kindly ask you to return us the complete  H-MAN X 2

 

together with a 

short description of the defect. 

 
First Use 

Components: 

The H-MAN X 2 includes the following parts: 

 

The head incl. electronic system, counter, reset magnet and headphones 

 

2 sets of LR6 batteries 

 

2 folder racks incl. screws and result cards 

 

Instruction card sized to fit the card bag on the folder rack 

 

1 ball pen holder self-adhesive 

 

Start-up:  

You have received the H-MAN X 2 ready for immediate use. You only need to screw the 

folder rack on the H-MAN X 2. 
Put on the headphone and press the start button. As soon as a light emitting diode will light up you are 
supposed to hear a tone. The frequencies are played alternately on either side of the headphone. The 
test begins on the right at 0,5 kHz and ends on the left at 4 kHz. 
In case the tones should be too soft or too loud (background noises) for your location, you may 
readjust the sound level (see functional characteristics) 
 

Functional Characteristics 

Important to know:  

The hearing tester is operated by means of batteries ( 4 pcs. LR6 of 1,5 V each) 

which allows its use in any location. The test frequencies are 4 tones on either side 0,5/1/2/4 kHz. 
 
You only need to remove the back cover panel in order to customize the H-MAN X 2.  
For this purpose gently remove the 2 screws at the back cover panel.  
Before doing so it is recommended to put the head onto a soft pad in order to avoid damages. To fix 
the back cover panel you should place it on the opening and insert the screws. 
 

A.  To change the batteries, the battery cover is removed from the back panel by means of a 

screw driver. Please mind the correct polarity of the batteries. 

 

B.  The next page includes a diagram to facilitate finding the position of the pad trimmers 

(adjustable resistors), DIP switches and contacts on the circuit board. You will have the 
following options for your customized design: 

 

The master volume level can be adjusted by means of the external pad trimmer at the back cover 
panel. In addition, the volume levels of the different frequencies can be customized for either side 
(0,5 kHz, 1 kHz, 2 kHz, 4 kHz). 
Upon delivery the output level of the external pad trimmer is adjusted at about 35 dB . By means 
of a screw driver it is possible to increase the volume level( turning clockwise) or to reduce it  
(turning anti-clockwise). The volume level of the individual tones can be increased by means of a 
screw driver (turning anti-clockwise) or reduced (turning clockwise). 

 

 

Содержание H-MAN X 2

Страница 1: ...r location you may readjust the sound level see functional characteristics Functional Characteristics Important to know The hearing tester is operated by means of batteries 4 pcs LR6 of 1 5 V each which allows its use in any location The test frequencies are 4 tones on either side 0 5 1 2 4 kHz You only need to remove the back cover panel in order to customize the H MAN X 2 For this purpose gently...

Страница 2: ...rnal DIP Switches Master Master 1 5 Volume level Volume level 1 2 3 4 5 0 5 1 2 4 Sound level kHz kHz kHz kHz Frequencies 1 2 3 4 0 5 1 2 4 kHz Headphone jack LEDs Power supply jack Battery Start Counter 9 12V 4x1 5V Button In case of additionally using a counter you will have the possibility to reset the same to 0 by means of a magnet included in the delivery For this purpose you only need to mov...

Страница 3: ... of the hearing tester can be continued without any problems In the event of a battery voltage of less than 5 V it is no longer possible to start the hearing tester Power input during operation about 11 mA After the automatic stop of the hearing tester the power input is less than 1µA multimeters normally in use do not allow to realize any measurements We recommend alkaline manganese batteries wit...

Страница 4: ... LED function with cycle continuing function The hearing test is started by pressing the start key for the first time As soon as a tone will be heard and the corresponding LED display will flash the repeated pressing of the start key will allow to confirm that the test person has heard the tone The LED of the heard tone remains flashing showing that the tone has been heard Then follows the next to...

Отзывы: