Wiring Instructions:
Important!
This unit is a safety device and it must be
connected to its own separate, fused power point to assure its
continued operation should any other electrical accessory fail.
Wire as shown in FIGURE 1. All wiring should be a minimum of 20 AWG. The positive line must have a slow blow 3 amp fuse. Routing the ground wire
directly back to negative battery terminal is recommended. Pack dielectric grease, such as Dow Corning 4, around each electric connection exposed to
moisture or the ambient environment. Isolate any unused wires.
FIGURE 1
Page 3 of 6
RED - POSITIVE
FUSE (3A)
(USER SUPPLIED)
BLUE - FLASH PATTERN SELECT
(MOMENTARY TO
GROUND), DIM (TO POSITIVE)
SWITCH
(USER SUPPLIED)
YELLOW (SYNC)
BLACK - GROUND
SWITCH
(USER SUPPLIED)
WHITE -
POSITIVE
(DUAL
COLOR ONLY)
SWITCH
(USER SUPPLIED)
ORANGE -
TAKEDOWN -
POSITIVE
SWITCH
(USER SUPPLIED)
GREEN -
PUDDLE LIGHT -
POSITIVE