Pattern Select Operation:

Notes on Synchronizing and Phase (Sync Ph):

Notes on Choosing Flash Patterns:

Notes on Dim Control:

The light head intensity may be reduced if necessary. The Blue wire when con-

nected to positive will reduce the intensity to 25% for SAE patterns. Light intensity 

for ECE patterns will reduce to 55%.

NOTE: The blue wire must be disconnected from any voltage when not activating 

DIM nor changing flash patterns.

The light head flash pattern may be changed by touching the Blue wire to ground for the following intervals (while the light head is flashing):

NOTE: The blue wire must be disconnected from any voltage when not activating DIM nor changing flash patterns.

- When the light head signal becomes steady, disconnect the Blue wire and the flash pattern will increment by one pattern.

- When the light head signal becomes steady, then goes off, disconnect the Blue wire and the flash pattern will decrement by one pattern.

- When the light head signal becomes steady, then goes off, then becomes steady again, disconnect the Blue wire and the flash pattern will reset to the factory default 

pattern.

- When the light head signal becomes steady, then goes off, then becomes steady again, then goes off again, disconnect the Blue wire and the flash pattern will become 

set to the steady burn mode.

Wiring Instructions:

RED: Positive, (5A fuse required)

WHITE: Positive, (5A fuse required)

BLACK: Negative

BLUE: Pattern select to negative -- Dim control to positive

YELLOW: Synchronized Function (Up to 32 units can be Synchronized)

            

         

Caution!

 

When drilling into any vehicle surface, 

make sure that the area is free from any electrical wires, 

fuel lines, vehicle upholstery, etc. that could be damaged.

Installation and Mounting:

            

Important!

 

 This unit is a safety device, and it must be 

connected to its own separate, fused power point to as-

sure its continued operation should any other electrical 

accessory fail.

To mount the light head, use the bezel as a template to mark the mounting holes. The 

supplied self-tapping #6 x 0.75” screws typically use 0.125” diameter holes but this may vary 

depending on the type of material and the thickness being tapped. Provide a minimum 0.50” 

diameter hole for the wires. Grommet the hole if possible and seal with RTV sealant.

It is important to note:

The light head has a small round hole covered with vent membrane that must face 

downward when mounting the light head.

A variety of flash patterns may be chosen for the light head. The Multi Color light heads are split vertically as separate lighted areas that may be chosen to operate alter-

nately. The areas are denoted by: Primary color 1&3 (color1 on the left side and color3 on the right, typically the same color) and Secondary color 2&4 (color2 on the left 

side and color4 on the right, typically the same color). This allows for patterns that flash right-left using various multiple color combinations.

A separate flash pattern may be assigned for the power wires red, white, or both connected together and the pattern operated depending which wire or wires are ener-

gized. Power the red or the white wires (or both together) then use the pattern select blue wire (touch to ground) to select the chosen flash pattern from the list below. 

See the legend at the top of the pattern list for compliance with various standards.

(Up to 32 light heads can be Synchronized by connecting their yellow wires).

When the yellow wires of the light heads are connected together, the group with 

Ph1 flash patterns will flash simultaneously. If the light heads in the second group 

are set to Ph2 flash patterns, they will flash alternately with the first group. To 

simplify the set-up of a synchronized installation, the following process is recom-

mended:

1. Before connecting the yellow wires together, choose the desired flash pattern 

for each light head. 

The patterns chosen must have the same flash 

rate for all light heads intended to be synchronized. (By definition 

a 75fpm light head will not sync with at 120fpm light head) 

To avoid 

confusion set each light head individually to the chosen flash pattern using 

the blue pattern select wire. Ph1 light heads will alternate with Ph2 light 

heads and simultaneously with all other light heads set to Ph1. Ph2 light 

heads flash simultaneously with all other light heads set to Ph2. It is also 

strongly recommended that the same style of flash pattern be used on all 

heads to produce the most effective warning pattern.

2. Connect the yellow synchronization wires together and check that the light 

heads are flashing in a synchronized manner as expected. If a pattern 

for one light head appears to be wrong, keep the yellow wire connected 

and use the blue pattern select wire to cycle forward or backward for 

that individual light head until the correct pattern is selected. Once that is 

completed verify the light head is synchoronized correctly.

PA

TTERN 

GROUP

RED 

WIRE 

LED 

Color 

1&3

WHITE 

WIRE 

LED 

Color 

2&4

RED & 

WHITE 

WIRE LED 

Color 1&3, 

Color 2&4

FLASH PATTERN

SYNC

Complies 

with

0

1-Default

Cycle Flash Color 1&3

no

1-Default

Cycle Flash Color 2&4

no

1-Default

Cycle Flash Color 1&3 and Color 2&4

no

1

2

2

Single 75FPM Ph1 Color 1 Sync Color 3

yes

SC

3

3

Single 75FPM Ph2 Color 1 Sync Color 3

yes

SC

4

Single 75FPM Ph1 Color 1 Alt Color 4

yes

5

Single 75FPM Ph2 Color 1 Alt Color 4

yes

2

6

Single 75FPM Ph1 Color 2 Sync Color 4

yes

SC

3

7

Single 75FPM Ph2 Color 2 Sync Color 4

yes

SC

4

4

8

Single 75FPM (Color 1 Sync Color 3) Alt (Color 2 Sync Color 

4) (Phase 1)

yes

SC

5

5

9

Single 75FPM (Color 1 Sync Color 3) Alt Color 2 Sync Color 

4) (Phase 2)

yes

SC

6

6

10

Single 75FPM Color 1 Alt Color 2 Alt Color 3 Alt Color 4

yes

2

7

11

Single 375FPM Ph1 Color 1 Sync Color 3

yes

8

12

Single 375FPM Ph2 Color 1 Sync Color 3 

yes

13

Single 375FPM Ph1 Color 1 Alt Color 4

yes

14

Single 375FPM Ph2 Color 1 Alt Color 4

yes

7

15

Single 375FPM Ph1 Color 2 Sync Color 4

yes

8

16

Single 375FPM Ph2 Color 2 Sync Color 4

yes

9

9

17

Single 375FPM (Color 1 Sync Color 3) Alt (Color 2 Sync Color 

4) (Phase 1)

yes

10

10

18

Single 375FPM (Color 1 Sync Color 3) Alt (Color 2 Sync Color 

4) (Phase 2)

yes

11

11

19

Single 375FPM Color 1 Alt Color 2 Alt Color 3 Alt Color 4

yes

For patterns that meet SAE J595 Class1 requirements for Red, Blue, 

Amber, and White, see 

S

 in chart!

For patterns that meet California Title 13 Class B requirements for 

Red, Blue, and Amber, see 

C

 in chart!

For patterns that meet ECE65 Class1 Cat X (night only )require-

ments for Red, Blue, Amber, see 

E1 

in chart!

For patterns that meet ECE65 Class2 Cat X (day & night) require-

ments for Red, Blue, Amber, see 

E2

 in chart!

Flash Patterns ED3744 and ED3755 - Multi Color: