Wire Functions:

Wire:

Function:

Red

Positive

Black

Negative

Yellow 

Sync

Blue

Flash pattern change to Negative

Flash Pattern Selection:

Apply Blue to Black wire:

Push Times:

Function:

0 ~ 1 sec.

next pattern

1 ~ 3 sec.

previous pattern

3 ~ 5 sec.

factory default pattern

5 ~  sec.

last pattern

Synchronisation:

Syncing capabilities are available with all compatible ECCO products via the yellow wire with the flash patterns indicated in the charts below:

1. Determine the desired style of flash pattern for each unit and set each unit individually (without the yellow wires connected together) to avoid confusion. It 

is also strongly recommended that the same style of flash pattern be used on all units to produce the most effective warning pattern. NOTE: Phases 1 and 2 

for each style of flash pattern in the table denote the relative timing between units connected in a synchronizing installation. To operate simultaneously, each 

unit must be set to the same phase (1 + 1 or 2 + 2); to operate alternately, units must be set to have the opposite phase (1+ 2 or 2 + 1). 

2. Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern on one unit appears 

incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct pattern is selected. Note: This will only 

change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.

3. If the yellow wire is unused, leave unconnected and insulated.

EB8160A LED Beacon Flash Patterns

PATTERN

MODE

DESCRIPTION

SYNC

FPM

SAE J845

T13

AUTO DIM

1

1

Single Flash Phase 1 

Yes

75

CLASS 1A

CLASS E

No

2

Single Flash Phase 2

Yes

2

3

Single Flash Phase 1 

Yes

120

CLASS 1A

Yes

4

Single Flash Phase 2

Yes

3

5

Double Flash Phase 1

Yes

75

CLASS 1A

CLASS E

No

6

Double Flash Phase 2

Yes

4

7

Double Flash Phase 1

Yes

120

CLASS 1A

Yes

8

Double Flash Phase 2

Yes

5

9

Quad Flash Phase 1

Yes

75

CLASS 1A

No

10

Quad Flash Phase 2

Yes

6

11

Quad Flash Phase 1

Yes

120

CLASS 1A

Yes

12

Quad Flash Phase 2

Yes

7

13

Slow Rotate Phase 1

Yes

120

No

14

Slow Rotate Phase 2

Yes

8

15

Fast Rotate Phase 1

Yes

150

No

16

Fast Rotate Phase 2

Yes

9

17

Rotate / Quad Phase 1

Yes

N/A

No

10

18

Pulse Phase 1

Yes

60

No

19

Pulse Phase 2

Yes

11

20

Steady Burn

No

N/A

No