Page 2 of 4
Wire Functions:
Wire:
Function:
Red
Positive
Black
Negative
Yellow
Sync
Blue
Flash pattern change to Negative
Flash Pattern Selection:
Apply Blue to Black wire:
Push Times:
Function:
0 ~ 1 sec.
next pattern
1 ~ 3 sec.
previous pattern
3 ~ 5 sec.
factory default pattern
5 ~ sec.
last pattern
Synchronisation:
Syncing capabilities are available with all compatible ECCO products via the yellow wire with the flash patterns indicated in the charts below:
1. Determine the desired style of flash pattern for each unit and set each unit individually (without the yellow wires connected together) to avoid confusion. It
is also strongly recommended that the same style of flash pattern be used on all units to produce the most effective warning pattern. NOTE: Phases 1 and 2
for each style of flash pattern in the table denote the relative timing between units connected in a synchronizing installation. To operate simultaneously, each
unit must be set to the same phase (1 + 1 or 2 + 2); to operate alternately, units must be set to have the opposite phase (1+ 2 or 2 + 1).
2. Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern on one unit appears
incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct pattern is selected. Note: This will only
change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.
3. If the yellow wire is unused, leave unconnected and insulated.
EB8160A LED Beacon Flash Patterns
PATTERN
MODE
DESCRIPTION
SYNC
FPM
SAE J845
T13
AUTO DIM
1
1
Single Flash Phase 1
Yes
75
CLASS 1A
CLASS E
No
2
Single Flash Phase 2
Yes
2
3
Single Flash Phase 1
Yes
120
CLASS 1A
Yes
4
Single Flash Phase 2
Yes
3
5
Double Flash Phase 1
Yes
75
CLASS 1A
CLASS E
No
6
Double Flash Phase 2
Yes
4
7
Double Flash Phase 1
Yes
120
CLASS 1A
Yes
8
Double Flash Phase 2
Yes
5
9
Quad Flash Phase 1
Yes
75
CLASS 1A
No
10
Quad Flash Phase 2
Yes
6
11
Quad Flash Phase 1
Yes
120
CLASS 1A
Yes
12
Quad Flash Phase 2
Yes
7
13
Slow Rotate Phase 1
Yes
120
No
14
Slow Rotate Phase 2
Yes
8
15
Fast Rotate Phase 1
Yes
150
No
16
Fast Rotate Phase 2
Yes
9
17
Rotate / Quad Phase 1
Yes
N/A
No
10
18
Pulse Phase 1
Yes
60
No
19
Pulse Phase 2
Yes
11
20
Steady Burn
No
N/A
No