3.SYSTEM OPERATION
3.1 Switch On
Warning:
Please check the installation again before turning on the system.
Step 1:
Turn on the battery switch on every battery module
Note:
The battery switch isolates the internal battery modules which are connected in series,
the battery switch should not be used to disconnect the batteries under load. Isolation
of battery under load is achieved via battery breaker.
Step 2 :
Open the battery breaker cover and turn on the battery breaker.