background image

 

19

 

Peripherals addr parameter 

1

Peripherals address

 

addr

 

FFFF   

 

 

inquire/configure local info 

0~FFF8 

 

 

inquire/configure info of whose network address is addr   

FFFE

FFFD

FFFC    inquire/configure info of which received broadcasting data 

---FFFE    broadcast to all modules 

---FFFD    broadcast to free modules

except sleeping modules

 

---FFFC    broadcast to coordinators and routers 

 

All information 

1

all_info

   

Identification     

  Length (position) 

    Description

 

dev_type   

 

1   Byte

0

 

   

Device type 

nwk_state        

1    Byte

1

 

   

Network state 

pan_id            

2    Byte

2~3

))

  

Network PAN_ID 

key 

         

16 Byte

4~20

))

 

Network key 

ShortAddr     

2    Byte

21~22

))

 

Network short address 

Mac_Addr     

8    Byte

23~30

))

 

MAC address 

Coor_shortAddr   

2    Byte

31~32

))

 

Father node short address   

Coor_Mac_Addr   

8    Byte

33~40

))

 

Father node MAC address 

group             

1    Byte

41

))

       

Network group no. 

channel           

1    Byte

42

))

     

Communication channel 

txpower         

1    Byte

43

))

     

Transmission power 

baud       

 

1    Byte

44

))

   

Serial baudrate 

sleep_time              

1    Byte

45

))

   

Sleep mode 

 

Example for parameter

 

all_info

   

  020102 F411 13 15 17 19 1B 1D 1F 10 12 14 16 18 1A 1C 1DF2 EF89 6C 50 09 00 4B 12 0000 0020 39 EA 0A 00 4B 12 00010B040905   

 

Device type

  02 

terminal

 

 

Network state

  01 

existing network

 

 

Network PAN_ID

  02 F4 

PAN_ID=0X02F4

 

 

Network key

  11 13 15 17 19 1B 1D 1F 10 12 14 16 18 1A 1C 1D   

 

Local short address

  F2 EF 

Local short Address=0XF2EF

 

 

Local MAC address

  89 6C 50 09 00 4B 12 00   

 

Father node short address

  00 00

Short Address=0X0000

 

 

Father node MAC address

  20 39 EA 0A 00 4B 12 00   

 

Network group no.

  01 

1

 

 

Communication channel

  0B 

11

 

 

Transmission power

  04 

4.5dBm

 

 

Serial baudrate

  09 

115200

   

 

Sleep mode

  05 

5 seconds

 

Note

Father node storage time is not included

if needs inquire or configuration

please use independent command

 

Содержание Z2530-2G4-20

Страница 1: ...twork User Instruction Manual This manual may change with the continuous improvement of the product Please refer to the latest version of the instruction Chengdu Ebyte Electronic Technology Co Ltd res...

Страница 2: ...ean industry standards Use temperature compensation circuit the frequency stability is better than 2PPM With operating temperature range 40 85 adapting to a variety of harsh working environment All wi...

Страница 3: ...routing function users can conduct multi hopping networking 8 Support encryption protocol The module uses AES 128 bit encryption function can change the network encryption and prevent monitoring User...

Страница 4: ...en the power is on 3 TX LED Transmit LED Yellow blinks when sending data 4 RX LED Receive LED Yellow blinks when reveiving data 5 LINK LED Link LED Red lit when no network off when network connected 6...

Страница 5: ...5 2 2 Dimension...

Страница 6: ...ption 1 VCC Screwing power interface positive 8 28V DC 12V or 24V recommended 2 GND Screwing power interface negative The power supply negative pole is connected to the system ground and the housing 3...

Страница 7: ...ordinator Data will be transmitted according to the fixed format protocol of data transmission There are point to point broadcast multicast transmission ways Please refer to HEX data communication des...

Страница 8: ...ls please confirm the work mode No Notes 1 Construct network Connect Zigbee ad hoc module via USB to UART converter Open host computer software Zigbee_Setting_V1 1 select Com port and set baud rate as...

Страница 9: ...ordinator write in parameter Wait the coordinator to start constructing network and users can check module parameter Set network parameter when PAN ID is FFFF it is automatic PAN ID Read parameter whe...

Страница 10: ...10 Select another module set it as the router or end device following the same steps module is set as end device when leave factory default no need to set again in this experiment it is end device...

Страница 11: ...mputer Corresponding info is available to be viewed Coordinator End device For users convenience to observe in this experiment it is HEX transmitting mode If the device address is unknown please input...

Страница 12: ...12 Input random content in these 3 modes click start Transparent transmission From coordinator to end device From end device to coordinator Network address From coordinator to end device...

Страница 13: ...13 From end device to coordinator MAC address From coordinator to end device From end device to coordinator Multicast...

Страница 14: ...HEX In this mode user can transmit with serial port assistant to be in temporary AT command mode then can configure with AT command and exit AT command mode by transmitting AT EXIT Note 1 Serial data...

Страница 15: ...ransmit FE 01 09 FF Return FB 01 Read communication channel Transmit FE 01 0A FF Return FB channel Transmit FE 01 0A FF Return FB 0B Read transmission power Transmit FE 01 0B FF Return FB txpower Tran...

Страница 16: ...F 6 2 HEX Parameter Description Network type dev_type 00 coordinator 01 router 02 terminal default Network state nwk_state 00 no network 01 network Network PAN_ID pan_id 0000 FFFE fixed network PAN_ID...

Страница 17: ...19 05 Serial baudrate baud baudrate contrast baud baudrate baud baudrate 00 2400 08 76800 01 4800 09 115200 default 02 9600 0A 128000 03 14400 0B 230400 04 19200 0C 256000 05 38400 0D 460800 06 43000...

Страница 18: ...state invalid level 0 low 1 high 2 flipping PWM parameter 1 PWM port pwmx PWM port contrast pwmx duty1 duty2 duty3 duty4 duty5 GPIO P0_2 P0_3 P0_4 P0_5 P0_6 2 pwm cycle period 0 FFFF cycle tim unit 1...

Страница 19: ...C address group 1 Byte 41 Network group no channel 1 Byte 42 Communication channel txpower 1 Byte 43 Transmission power baud 1 Byte 44 Serial baudrate sleep_time 1 Byte 45 Sleep mode Example for param...

Страница 20: ...be sent command 02 group data parameter description group 0 99 number e g FC 05 02 01 31 32 33 description transmit HEX data to network group no 1 0X31 0X32 0X33 3 Point to point transmission content...

Страница 21: ...uire configure operating mode Format Inquire transmit AT MODE return MODE type CR LF configure transmit AT MODE mode return OK CR LF Parameter mode 1 mode 1 transparent transmission mode 2 mode 2 half...

Страница 22: ...PANID Function inquire configure network PANID Format inquire transmit AT PANID return PANID panid CR LF configure transmit AT PANID mode return OK CR LF Parameter panid 0000 FFFE fixed PANID FFFF ra...

Страница 23: ...e MAC address unique IEEE ID e g AT MAC_ADDR AT COOR_SHORT_ADDR Function inquiry father node network short address Format inquiry transmit AT COOR_SHORT_ADDR return COOR_SHORT_ADDR macaddr CR LF Param...

Страница 24: ...AT GROUP return GROUP group CR LF configure transmit AT GROUP group return OK CR LF Parameter group 0 99 Local group no e g AT GROUP group Default GROUP 1 AT CH Function inquiry configure communicatio...

Страница 25: ...serial baudrate e g AT UART 9 Default UART 9 AT SLEEP Function inquiry configure sleep mode valid for terminal Format inquiry transmit AT SLEEP return SLEEP sleep CR LF configure transmit AT SLEEP sle...

Страница 26: ...g AT SOFT_ID AT RESET Function reset Format configure transmit AT RESET return OK CR LF e g AT RESET AT RESTORE Function restore factory settings Format configure transmit AT RESTORE return OK CR LF...

Страница 27: ...5 AT GPIO_LEVEL Function read remote local GPIO input output mode Format configure transmit AT GPIO_LEVEL addr gpiox level return OK CR LF Parameter addr 0000 FFF8 remote short address device FFFF loc...

Страница 28: ...duty5 0 65535 unit 1 62 5ns the positive pulse duration of the corresponding channel PWM is closed when it is 0 or greater than the cycle e g AT PWM 1AC0 1000 1 500 500 0 500 AT RPWM Function read re...

Страница 29: ...user by default it is 30 seconds ranging from 0 to 120 seconds 4 Only the end device has the sleep function sleeping within 250S the user can set by themselves the default 0 with sleep mode off Note T...

Страница 30: ...12 PWM function and sleep mode can not be used at the same time in network please turn off the sleep mode before turn on PWM function 13 After sleep mode it can be waked up via the serial port UART N...

Страница 31: ...istribution network automation hydrological and hydrological forecasting water pipe network monitoring urban street lamps Monitoring air defense alarm control railway signal monitoring centralized con...

Страница 32: ...erature humidity low temperature strong electromagnetic fields or dust larger environment 6 Please do not continuously keep transceiver to transmit in full capacity or the transmitter might be damaged...

Страница 33: ...In addition for special requirements we agree to offer certain amount of documents according to order quantity not every data transceiver are supplied with one manual please understa CDEBYTE after sal...

Отзывы: