2.6 RF exposure considerations 

 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 

operated with minimum distance 20cm between the radiator & your body. 

 

2.7 Antennas 

 

This radio transmitter Y8E-VM-LORA has been approved by Federal Communications Commission to operate with the antenna types listed below, 

with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any 

type listed are strictly prohibited for use with this device.   

Antenna No.   

Operate frequency band 

Antenna Type 

Maximum antenna gain 

Antenna 1 

902-928MHz 

External Antenna 

1.5dBi 

 

2.8 Label and compliance information 

 

The final end product must be labeled in a visible area with the following" Contains FCC ID:Y8E-VM-LORA".

 

 

2.9 Information on test modes and additional testing requirements

 

Host manufacturer is strongly recommended to confirm compliance with FCC requirements for the transmitter when the module is  installed in the 

host. 

 

 

2.10 Additional testing, Part 15 Subpart B disclaimer 

 

Host manufacturer is responsible for compliance of the host system with module installed with all other applicable requirements for the system such 

as Part 15 B.       

 

8.

 

About US 

Technical support: 

[email protected] 

Documents and RF Setting download link: 

www.cdebyte.com/en/ 

 

                                                                                                                                       

Tel

+86-28-61399028                                                                                                                     

Fax

028-64146160                                                                                               

Web

www.cdebyte.com/en/ 

Address

Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China       

 

 

Содержание LoRa SX-1276 1W

Страница 1: ...mplifier enhanced the communication stability and communication distance The 20dBm module integrated the industrial crystal oscillator accuracy is less than 10ppm with stable batch production and widely used for utilities IOT transformation and smart home The related RF parameters can get through the domestic and overseas certification such as FCC CE RoHs etc satisfying export demand Model No RF I...

Страница 2: ...Receiving current 3 1 2 3 Turn off current 3 1 2 4 Supply voltage 3 1 2 5 Communication level 4 1 3 RF PARAMETERS 4 1 3 1 Transmitting Power 4 1 3 2 Receiving sensitivity 4 1 3 3 Recommended Frequency 4 1 4 TESTED DISTANCE 5 2 PIN DEFINITION 5 3 USAGE 6 4 REMARK 6 5 PRODUCTION GUIDANCE 7 5 1 REFLOW TEMPERATURE 7 5 2 REFLOW GRAPH 7 6 FAQ 7 6 1 THE COMMUNICATION DISTANCE IS TOO CLOSE 7 6 2 THE MODUL...

Страница 3: ...fect the transmitting current value at different levels 1 2 2 Receiving current Model No Min Typ Max Unit Remark LoRa SX 1276 1W module 21 2 23 0 25 3 mA The current consumed when the RF chip is only working at receiving mode is called as receiving current the tested receiving current may be higher for some RF chips with communication protocol or the developers have loaded their own protocol to th...

Страница 4: ...Ra SX 1276 1W module 29 6 30 0 30 5 dBm Due to the error of the materials each LRC component has 0 1 error so error accumulation will occur since multiple LRC components are used in the whole RF circuit and the transmitting currents will be different at different modules The power consumption can be lowered by lowering the transmitting power but the efficiency of the internal PA will be decreased ...

Страница 5: ... 30 bytes in each packet the range at data lose rate of lower than 5 is valid range In order to obtain meaningful and reproduceable results we conducted the tests under in clear weather with little electromagnetic interference at suburb areas Distance may be shorter with interference or obstacles 2 Pin definition 2 1 2 LoRa SX 1276 1W module Pin No Name Direction Usage 1 GND Ground electrode conne...

Страница 6: ...TXEN pin is in high level RXEN pin is in low level when transmitting 17 RXEN Input Radio frequency switch control Make sure the RXEN pin is in high level TXEN pin is in low level when receiving 18 GND Ground electrode connected to the power reference ground 19 ANT Antenna 20 GND Ground electrode connected to the power reference ground 21 GND Ground electrode connected to the power reference ground...

Страница 7: ...rature rise is 2 5 s Recirculation zone Maximum temperature is 235 245 Above 217 the time will be 40 80s Cooling zone Maximum cooling is 4 s 5 2 Reflow Graph 6 FAQ 6 1 The communication distance is too close When there s straight Communication barrier the communication distance will be reduced accordingly Temperature humidity and same frequency interference will increase the rate of communication ...

Страница 8: ...uipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions m...

Страница 9: ...e Antenna No Operate frequency band Antenna Type Maximum antenna gain Antenna 1 902 928MHz External Antenna 1 5dBi 2 8 Label and compliance information The final end product must be labeled in a visible area with the following Contains FCC ID Y8E VM LORA 2 9 Information on test modes and additional testing requirements Host manufacturer is strongly recommended to confirm compliance with FCC requir...

Отзывы: