2.2.3 Step 3: Receive (output) end product signal output wiring
(1) According to the figure 2-3 below, connect the DO and GND wires of the output end of K61-04 of this product
according to the figure below (or connect them to the switch signal acquisition sensor). After receiving the switch signal
sent by the sender, the K61-04 device will output a closed switch signal, the light bulb in the picture will be on, and the
corresponding IO light will be always on.
(2) Notes:
a. The output of this product is a switch signal, and it will not output voltage;
b. When the devices are powered on (sending and receiving), check the "NET" light of the K61-04 device, if the "NET"
light is on, the communication between the two devices is successfully established;
c. When the corresponding IO light is on, it means that the K61-40 sender receives a switch signal, and the K61-04
output terminal outputs a closed switch signal:
d. When the terminal is connected to the wire, please tighten the screw on the plug-in terminal of this product, and pay
attention that the conductive part of the terminal cannot be pressed against the insulation layer of the wire, so as to avoid
poor contact.
(For more details, see the "FAQ" section)
Figure 2-3 Connecting IO ports
2.2.4 Step 4: Power on the product and observe the status of the indicator
lights
(1) Plug the two 12V/1A adapters into the power strip (mains AC220V), and the entire system is powered on.
(2) Observe the status of the indicator light, the sending end collects the digital signal and the receiving end outputs the