Subcontractin
g interval
(ms)
1
The value that can be filled in is 1~255. When
the CAN port does not receive new data frames
within the time defined by the "packet time
interval" (unit: ms) and the number of packet
frames has not been reached, all data frames
that have been received and have not been sent
before will be packaged into an Ethernet packet
and sent to the network port.
category
name
default
explain
CAN
configurat
ion
Standard
frame upper
limit
7FF(HEX) The upper limit and lower limit of the
received standard frame ID set by the user
jointly determine the standard frame ID range
to be received.
Lower limit of
standard
frame
000(HEX)
Extended
frame upper
limit
1FFFFFFF
(HEX)
The upper limit and lower limit of the received
extended frame ID set by the user jointly
determine the range of extended frame IDs to
be received.
Lower limit of
extended
frame
000000000