Customize the interval for sending heartbeat packets. When it is set to 0, the heartbeat packet function is turned off. If the
setting value is greater than zero, the heartbeat packet function is turned on. When it is turned on, the range can be set:
(1-65536) seconds.

4.3.3 Registration package function

In the client mode, the user can choose to send the registration package, and set the registration package time by
definition.
The registration package supports the following modes:
(1) The MAC address (OLMAC) is sent when the network establishes a connection with the device.
(2) The data of the custom registration package sent when the network establishes a connection with the device
(OLCSTM).
(3) After the network and the device are connected, each packet of data sent by the device to the network is preceded by a
MAC address (EMBMAC).
(4) After the network and the device are connected, each packet of data sent by the device to the network is prepended
with custom registration packet data (EMBCSTM).
Custom registration package content (maximum support 40 bytes (ASCII) data, 20 bytes (HEX) data).

4.3.4 Short connection function

In client mode, short network connection is supported (this function is disabled by default). TCP short connection is
mainly used to save server resource overhead, and is generally used in multi-point (multi-client)-to-point (server)
scenarios.
In client mode, short network connection is supported (this function is disabled by default). TCP short connection is
mainly used to save server resource overhead, and is generally used in multi-point (multi-client)-to-point (server)
scenarios.
When the short link hold time is set to 0, the short link function is turned off. When the setting range is (2-255) seconds,
the short connection function is enabled, and the default hold time is 0 seconds (disabled).

4.3.5 Timeout restart function

Supports the timeout restart function (default: 300 seconds), which is mainly used to ensure the long-term stable
operation of the device. If data is not sent and received within the set timeout restart time, the device will restart to avoid
the impact of abnormal conditions on communication.
The parameter range of timeout restart time is (60-65535) seconds. If it is set to 0, it means shutdown timeout restart. The
default is 300 seconds.

4.3.6 Cache cleaning function

The device is in the client mode. When the TCP connection is not established, the data received by the serial port will be
placed in the buffer area. The serial port receiving buffer is 1024 bytes, and the data larger than 1024 bytes will cover the

Содержание EBT3001

Страница 1: ...Chengdu Ebyte Electronic Technology Co Ltd EBT3001 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 1 EBT3001...

Страница 2: ...actory settings 13 4 2Socket function 13 4 2 1 TCP server mode 13 4 2 2 TCP Client Mode 14 4 2 3 UDP Server Mode 14 4 2 4 UDP Client Mode 14 4 2 5 HTTP Client Mode 14 4 2 6 MQTT Client mode 16 4 3 Adv...

Страница 3: ...ctronic Technology Co Ltd EBT3001 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 2 5 2 Configuration tool software settings 27 5 3 AT command configuration 27 Revise histor...

Страница 4: ...Even Mark Space Support DHCP function Support DNS function domain name resolution DNS server address customization Support a variety of Modbus gateways simple protocol conversion multi host mode stor...

Страница 5: ...onic Technology Co Ltd EBT3001 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 4 2 Size and pin definition 2 1 Package size This chip adopts standard QFN48 package QFN48 5 5...

Страница 6: ...ives RX signal end 12 RX_Women I O A Ethernet receives RX signal end 13 TX_P I O A Ethernet sends TX signal terminal 14 TX_WOMEN I O A Ethernet sends TX signal terminal 17 TXD0 I O A Serial port sendi...

Страница 7: ...t is recommended to be no less than 0 1uF and it is recommended to connect VDCID through magnetic beads or directly 36 IO_RST I O A To restore the factory side an external reset button is required and...

Страница 8: ...ucts PN Type Socket Operating mode Operating Voltage Product Size mm NS1 SMD module 6 way TCP Sever TCP Client UDP Sever UDP Client MQTT Client HTTP Client 3 0 5 5V DC 17 19 4 NT1 In line module 6 way...

Страница 9: ...tion method Web configuration tool AT command IP address Customizable default 192 168 3 7 Local port Customizable default 8887 Subnet mask 255 255 255 0 Gateway Customizable default 192 168 3 1 Target...

Страница 10: ...Co Ltd 9 3 3 Default parameters Project Default parameters IP address 192 168 3 7 Default local port 8887 subnet mask 255 255 255 0 default gateway 192 168 3 1 Default working mode TCP Server Default...

Страница 11: ...Chengdu Ebyte Electronic Technology Co Ltd EBT3001 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 10 3 4 Hardware design 3 4 1 Typical application hardware connection...

Страница 12: ...icrosoft Edge version 94 0 992 50 is an example it is recommended to use Google kernel browser IE kernel browser is not supported Step 1 Open the browser enter the IP address of the device in the addr...

Страница 13: ...need to enter 192 168 3 7 8080 in the address bar to connect to the web page configuration 4 1 2 Subnet mask IP address The IP address is the identification of the module in the local area network an...

Страница 14: ...router is connected to the external network the gateway is the router 4 1 3 Domain Name Resolution DNS Domain name resolution translates domain names into network recognized IP addresses through Doma...

Страница 15: ...device should be less than 512Bit per packet otherwise it will cause data loss 4 2 4 UDP Client Mode UDP Client is a connectionless transmission protocol that provides transaction oriented simple and...

Страница 16: ...onic Technology Co Ltd 15 Configure the local network parameters and the HTTP server address and port You are advised to enable DHCP and random ports As shown in the figure below Above is the upper co...

Страница 17: ...al port server supports quick access to standard MQTT3 1 1 protocol servers OneNET Baidu Cloud Huawei Cloud user built and other server types and Alibaba Cloud servers supports service quality level c...

Страница 18: ...te Electronic Technology Co Ltd 17 To use MQTT function advanced Settings such as short links should be turned off as shown in the figure below upper computer and webpage configuration as shown below...

Страница 19: ...a topic for communication testing Select the corresponding product go to Custom Topic under the Topic class list for details please refer to the Alibaba Cloud documentation click Define Topic Class se...

Страница 20: ...lient modes 4 3 2 Heartbeat Packet Function In client mode users can choose to send heartbeat packets and set the time of heartbeat packets by themselves The heartbeat packet can be selected in two mo...

Страница 21: ...unction In client mode short network connection is supported this function is disabled by default TCP short connection is mainly used to save server resource overhead and is generally used in multi po...

Страница 22: ...each attempt of the device to re establish the network Number of reconnections The number of times the device tries to re establish the network and the cumulative number of requests reaches the preset...

Страница 23: ...o be upgraded Step 4 Click to start the upgrade the device indicator flashes and wait for the upgrade to complete Note When the device is just powered on click Search Device in the upgrade assistant t...

Страница 24: ...t is working in there can only be one Modbus master station Simple protocol conversion configuration TCP server mode as an example the upper computer on the left web page on the right 4 4 3 Multi host...

Страница 25: ...ears the cache to ensure the real time and authenticity of the data 3 The polling interval can be customized 0 65535ms 4 The gateway will poll the RTU device according to the storage time of the instr...

Страница 26: ...ure web page 4 4 6 Automatic upload In client mode TCP client UDP client etc the gateway will automatically poll the instructions in the stored instruction table and upload it to the server and the fe...

Страница 27: ...du Ebyte Electronic Technology Co Ltd EBT3001 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 26 TCP client demo Modbus RTU format on the left and Modbus TCP format on the r...

Страница 28: ...mpatibility mode QQ browser compatibility mode and other browsers using IE core are not supported to use web page configuration 5 2 Configuration tool software settings Open the configuration tool sof...

Страница 29: ...ology Co Ltd Revise history Version Date Notes Reviser 1 0 2022 06 01 Initial version Xxn About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you...

Отзывы: