Chengdu Ebyte Electronic Technology Co.,Ltd.
E95-DTU(900SLxx-485) User Manual
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
power supply
E95-DTU(900SL30-4
85)
850.125
~
930.125
30
10
New
generation
LoRa
spread
spectrum,
DC
power supply
long-distance,
interference-prone
environments.
Note: Sunny weather, open environment without obstruction, 12V/1A power supply, 5dBi suction cup antenna,
antenna height 2 meters from the ground, use factory default parameters.
3.2 General Specifications
number
name
Specification
explanation
1
Size
92*66*30 mm
See installation dimensions for details
2
Weight
95 g
Weight tolerance 5g
3
Working
temperature
-40℃
~
+85℃
Industrial grade
4
Voltage range
8
~
28V
(
DC
)
12V or 24V recommended for DC version
5
Communicatio
n interface
RS485
RS485
6
baud rate
出厂默认
9600
Baud rate range 1200
~
115200
7
address code
出厂默认
0
A total of 65536 address codes can be set
3.3 Frequency range and number of channels
Model Specifications
Default
frequency
Frequency range
channel
spacing
number of channels
Hz
Hz
Hz
E95-DTU(900SLxx-485)
850.125M
850.125
~
930.125M
1M
81
,
half duplex
Note: In the same area, multiple groups of digital radios are used for one-to-one communication at the same time. It
is recommended that each group of digital radios should be set to a channel interval of more than 2MHz.
3.4 transmit power level
Model Specifications
22dBm / 30dBm
17dBm / 27dBm
13dBm / 24dBm
10dBm
/
21dBm
E95-DTU(900SLxx-48
5)
Factory default
√
√
√