station to actively Listen to the environmental noise of the channel after sending data to the server. If the noise
exceeds the threshold, the transmission will be delayed. This function can greatly improve the success rate of
radio communication with radio frequency in harsh environment. This function can be used for network
transmission and conflict prevention.

5

Fixed point transmission: support address function, radio frequency terminal can transmit data to

other wireless devices at any address and any channel to achieve networking, relay and other applications: for
example, the radio needs to transmit data to E22 cofrequency series module B (address 0x00 01, channel 0x80),
and its communication format is: 0001 80 AA BB CC, where 0001 is the address of module B and 80 is the
channel of module B, then module B can receive AA BB CC, and other modules do not receive data (the same
is true for E90-DTU (xxx-SLXX) series stations).

6

LoRa spread spectrum: LoRa direct sequence spread spectrum technology will bring more

communication distance; Low transmission power density, not easy to cause interference to other equipment;

9

Factory recovery

There are two ways to restore the factory

Software restore factory: users can configure software through the E90-DTU (400SL30-GPRS) officially
provided. In the configuration mode of GPRS/2G network transmission and RF configuration mode, click
the "restore from factory" button to reset the GPRS/2G module and RF module. Note: if the "restore
factory" button is clicked in the configuration mode of GPRS/2G network pass-through, after all
parameter modification operations are completed, the "module restart" button should be clicked again to
enable the restored factory or configured GPRS/2G network pass-through parameters to take effect.

Hardware restore factory

The user can press the Reload button on the side of the radio station for 4~10S

and all parameters will be restored to the factory setting. At this time, the system will automatically
switch to the communication mode.

Содержание E90-DTU 400SL30-GPRS

Страница 1: ...E90 DTU 400SL30 GPRS...

Страница 2: ...chnology Co Ltd 1 1 OVERVIEW 2 1 1 INTRODUCTION 2 1 2 FEATURES 2 1 3 STATION SYSTEM PARAMETERS 3 1 4 PIN DESCRIPTION 5 1 5 PIN DEFINITION 6 1 6 SIZE 7 2 QUICK START 8 2 1 HARDWARE PREPARATION AND COMM...

Страница 3: ...network data connection E90 DTU 400SL30 GPRS can be directly connected to the upper computer via USB cable for parameter configuration without the need to install the driver it is easy to change user...

Страница 4: ...connection and other functions 1 3 Station system parameters Parameter type Parameter Name The parameter value Description NET Characteristic parameters Support Frequency Quad frequency GSM850 EGSM90...

Страница 5: ...93 125MHz Default 433 125MHz channel number 84 channel interval 1MHz Transmission power 30dBm About 1W level 4 adjustable 30 27 24 21dBm Receiving sensitivity 138dbm 0 3kbps The receiver sensitivity i...

Страница 6: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 5 1 4 Pin Description...

Страница 7: ...eset button long press time no requirement 6 USB Micro USB parameter configuration interface 7 Reload Press 4 10s to restore the factory Settings 8 PWR Red power indicator 9 WORK Yellow data transmiss...

Страница 8: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 1 6 Size...

Страница 9: ...the PWR indicator will always be on E90 DTU 400SL30 GPRS device and E22 400TXXS module 5V 20V Power adapter USB switch to TTL module and USB wire GPRS LTE Sucker antenna Computer browser visit Chengd...

Страница 10: ...ion tool If the USB is correctly connected the message box on the right side will prompt device ready 3 After entering the GPRS 2G network pass through configuration mode the parameters of GPRS 2G mod...

Страница 11: ...the RF module in the setting of relevant parameters After the configuration is completed click the save RF parameters button After completion as shown in the following figure 5 After the configuratio...

Страница 12: ...e restart button and directly click the enter communication state button in the RF mode After completion as shown in the following figure 6 Within 30 seconds after the communication state is entered i...

Страница 13: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 12 8 Use the serial port assistant to send data to E22 400TXXS module If E90 DTU 400SL30 GPRS receives the data sent by E22 230TXXS the W...

Страница 14: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 13 b E90 DTU 400SL30 GPRS sends data to E22 400TXXS...

Страница 15: ...ws users to configure radio RF parameters d Mode switch use the official E90 DTU 400SL30 GPRS to configure the upper computer for mode switch and parameter configuration Note that after using the uppe...

Страница 16: ...the local cache is 256 bytes 7 The cloud transmission function of Ebyte IOT platform Users can use the official E90 DTU 400 SL30 GPRS configuration software GPRS 2 G network passthrough configuration...

Страница 17: ...C and other modules do not receive data the same is true for E90 DTU xxx SLXX series stations 6 LoRa spread spectrum LoRa direct sequence spread spectrum technology will bring more communication dista...

Страница 18: ...0SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 17 3 Application model 1 E22 400TXXS E90 DTU 400SL30 GPRS Server A 2 E90 DTU 400SLxx E90 DTU 400SL30 GPRS Server A...

Страница 19: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 4 E90 DTU 400SLxx E90 DTU 400SL30 GPRS Server A Server B...

Страница 20: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL30 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 19 5 Ebyte cloud transmission 6 Application in buildings...

Страница 21: ...wered on normally The status bar of the upper computer device shows no valid device found Check whether the USB cable and power cord are connected correctly If they are connected try to press the Rese...

Страница 22: ...sion of the manual shall prevail Users of the product shall follow the product trends on the official website so that users can timely obtain the latest information of the product Version Date Revisio...

Отзывы: