Chengdu Ebyte Electronic Technology Co., Ltd.
E830-DIO(ETH-2A) User Manual
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
3
1. Electrical Parameters
No.
Name
Value
Description
1
Size
82 * 84 *25mm
Without screwing interface
2
Average weight
118±2g
Without screwing interface
3
Input channel
2 way double end digital
input
6-28V input voltage difference will be valid.
4
Output channel
2 way single end digital
output
NPN Transistor collector open-drain outputs.
5
Interface
2 * 4 * 3.81 mm
Screwing way
6
Power supply
voltage
8 ~ 28V DC
Note: The voltage cannot be higher than 28V, or
module will be destroyed.
7
Working current
40mA@24V
40mA in normal status. 54mA in data transmitting
8
Device address
0-248
0-248 are configurable
,
default is 1
9
Working
temperature
-40℃
~
+85℃
Industrial grade
10
Isolation
protection
4000V DC
Lightning strike and surge protection
1.1 E830 Series
Model No.
Size
Interfac
e
Signal type
Input
channel
Output
channel
Protection
level
V DC
E830-DIO (485-8A)
82*84*25
RS485
Digital
8
8
4000
E830-DIO(ETH-2A)
82*84*25
RJ45
Digital
2
2
4000
1.2 FAQ
NO.
Question
Description
1
connect to network, but cannot read
parameters with Modbus
Reset device reconfiguration.
2
Forget parameters
It can resume the factory settings by pressing the touch button
5S, and then reset it. This recovery is only for Ethernet
parameter and MODBUS register.