OK
Precautions
Need to set before sending data
command
characters
Command
type
command format
response
CAPPPORT
(
Set the uplink
data port
number
)
test
command
AT+CAPPPORT=?
+CAPPPORT:
"
value
"
OK
query
command
AT+CAPPPORT?
+CAPPPORT:<value>
OK
set command
AT+CAPPPORT=<value>
OK
Parameter
Description
<value>: as follows:
The port used, the data format is decimal, and the factory value is 10.
Value range: 1~223;
Note: Port: 0x00 is the LoRaWAN MAC command
Return value
description
Example
AT+CAPPPORT=10
OK
Precautions
Need to set before sending data
command
characters
Command
type
command format
response
CADR
(set rate
adaptive)
test
command
AT+CADR=?
+CADR:"value"
OK
query
command
AT+CADR?
+CADR: <value>
OK
set command
AT+CADR=<value>
OK
Parameter
Description
<value>: as follows:
0: Turn off ADR
1: Enable ADR
Return value
description
Example
Precautions
command
characters
Command
type
command format
response
CDATARATE
(
Set the
communication
rate
)
test
command
AT+CDATARATE=?
+CDATARATE:
"
value
"
OK
query
command
AT+CDATARATE?
+CDATARATE:<value>
OK
set command
AT+CDATARATE =<value>
OK
Parameter
Description
<value>: as follows:
Rate value, the factory value is 3, the value range:
0 - SF12, BW125
1 - SF11, BW125
2 - SF10, BW125
3 - SF9, BW125
4 - SF8, BW125
Return value
description