![Ebyte E72-2G4M02S2B Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/ebyte/e72-2g4m02s2b/e72-2g4m02s2b_user-manual_530547012.webp)
Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2020
,
Chengdu Ebyte Electronic Technology Co., Ltd
11
AT+CONIN
Query/Set connection interval
AT+ADVON
Open advertising
AT+ADVOFF
Close advertising
AT+TXPWR
Query/Set power
AT+RSSI
Acquire the RSSI of connected device
AT+DISCONN
Disconnection
AT+UUID
Query/Set UUID
AT+ADVDATA
Query/Set advertising data
AT+IBEACON
Query/Set IBEACON data
AT+SCAN
Scan advertising device
AT+CONNECT
Connect to specified device
6.3 Mode switching
Command
Description
Echo
+++
Mode switching
CMD IN
,
CMD OUT
This command is used to switch to the command mode after the device has been connected, or to enter the transparent
transmission from the command mode. The transparent mode enters the command mode to generate the echo CMD IN,
and enters the transparent mode from the command mode to generate the echo CMD OUT.
6.4 Reset
Command
Description
Echo
AT+RESET
System Reset
Null
After executing this instruction, the module generates a reset operation.
6.5 Restore the default settings
Command
Description
Echo
AT+ FACTORY
Restore the default
settings
OK--AT+FACTORY: Factory Mode SUCCESS
After executing this command, the module will be restored to factory settings and will be valid after reset.
6.6 Query version information
Command
Description
Echo