Ebyte E70-915NW14S Скачать руководство пользователя страница 18

Chengdu Ebyte Electronic Technology Co.,Ltd

E70-915NW14S User Manual

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co.,Ltd

17

1

“ +++” enter AT Command

+++

Parameter specification:

Null

Response:
Enter AT Mode

Example

+++

Note: 1. The AT command can be used only after entering the AT command mode

2. After entering the AT command mode, the AT command mode can be used again only after exiting the AT

command mode, reset or restart the module

3. When writing this command, the serial debugging assistant must be set not to send new lines; writing other AT

commands must be set to send new lines.

2

AT+EXIT

Exit AT command mode

AT+EXIT

Parameter specification:

Null

Response

Exit AT Mode

Example

AT+EXIT

Note: AT commands are invalid after exiting AT command mode

3

AT+CNCFG

Set / Query device channel

AT+CNCFG=?

Parameter specification:
Query the current working channel
Response

Channel

0

AT+CNCFG=Value

Parameter specification:
Value

0~63

Factory default parameter is 0

Note: 1. In the long-distance mode and standard transmission mode, the frequency range is (908.2MHz ~ 920.8MHz), the

channel interval is 0.2MHz, and Fre = 908.2 + (Channel * 0.2);

In high-rate mode, the frequency range is 902.4MHz ~ 927.6MHz, the channel interval is 0.4MHz, and Fre = 902.4

+ (Channel * 0.4);

2. After setting the channel, the network information will be cleared

4

AT+ WMCFG

Set / Query the device's working mode configuration (restart to take effect)

AT+ WMCFG =?

Parameter specification:

Query the current working mode

Response

WMCFG

4

AT+ WMCFG =Value

Parameter specification:

Value

0~4

0

Coordinator

1, Normal node;

2, Dormant Node

3, Sleep mode

4, Pin control (factory default)

Example

AT+ WMCFG =4

Note: 1. After setting a new mode, it needs to be reset or power off and restart

2. After setting the mode, the network information will be cleared

5

AT+DINFO

Device information acquisition

AT+DINFO=SELFS

Parameter specification:
Acquire its own short address and return it through the serial
port.

Содержание E70-915NW14S

Страница 1: ...E70 915NW14S User Manual...

Страница 2: ...8 5 Firmware transmitting mode 10 5 1 Transparent transmission 10 5 2 Short address transmission 10 5 3 Long address transmission 11 6 Device status 11 6 1 AUX description 12 6 2 LINK description 13 6...

Страница 3: ...Chengdu Ebyte Electronic Technology Co Ltd E70 915NW14S User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 Revision history 24 About us 24...

Страница 4: ...duction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided...

Страница 5: ...4S strictly follows design standards of FCC CE CCC and meets various RF certification requirements for exporting Model No Frequency Transmit power Reference distance PCB IPX Package Antenna E70 915NW1...

Страница 6: ...orage temperature E70 915NW14S 16 26 mm 1 65 0 1g 40 85 10 90 40 125 C 3 2 Electrical parameters 3 2 1 Transmit current Model No Min Typ Max Unit Remark E70 915NW14S 27 mA When designing the power sup...

Страница 7: ...ers to the current consumed by the CPU RAM clock and some registers reserved and the SoC is in a very low power consumption state Sleep current is often much smaller than the current consumed by the p...

Страница 8: ...e error accumulation occurs resulting in a difference in transmission current of different modules Reducing the transmit power can reduce power consumption to some extent but reducing the transmit pow...

Страница 9: ...100 packets of data are sent each packet of data is 30 bytes and the packet loss rate is less than 5 is effective communication distance In order to obtain meaningful and reproducible test results we...

Страница 10: ...e connected in series externally and a 1M pull up resistor shall be added it shall not be suspended otherwise it can be grounded 19 RXD Input TTL UART inputs connects to external TXD output pin Can be...

Страница 11: ...be floated 37 NC Reserved pin Reserved to be floated 38 NC Reserved pin Reserved to be floated 39 NC Reserved pin Reserved to be floated 40 NC Reserved pin Reserved to be floated 41 GND Ground Ground...

Страница 12: ...broadcast address Coordinator HEX Sending 0A 01 AA 45 65 13 12 44 AA BB CC Node A address 0A 01 AA 45 65 13 12 44 HEX Receiving AA BB CC Node B address 0D 55 18 42 1A 27 29 64 HEX Null Node C address...

Страница 13: ...put can be used to wake up external MCU 2 Indication of wireless transmitting 1 The length of the buffer is 512 bytes and the single packet must not exceed 128 bytes when Aux 1 users can transmit data...

Страница 14: ...evice can receive data in extreme conditions sending device ACK pin indicates that the last data transmission failed 7 Operating mode 7 1 Coordinator mode If users configure the operating mode as 4 M0...

Страница 15: ...device was waken up the module will open the serial port receiving AT command if more than 2 seconds there is no data input the module will close serial port and go to sleep The sleep node is suitabl...

Страница 16: ...e AT mode is successfully entered As shown in Figure 5 1 Enter AT WMCFG 0 with line breaks to and configure the device as coordinator mode As shown in Figure 6 1 Figure 6 1 Then enter AT RSTART to res...

Страница 17: ...ting that the coordinator has started and is running After an normal node device starts up it will have a network access time of 5 to 20 seconds When the network access is completed the LINK pin will...

Страница 18: ...nse Channel 0 AT CNCFG Value Parameter specification Value 0 63 Factory default parameter is 0 Note 1 In the long distance mode and standard transmission mode the frequency range is 908 2MHz 920 8MHz...

Страница 19: ...g Address RSSI 6 Output Valid Data Short Address RSSI 7 Output Valid Data Long Address Short Address RSSI Example AT TFOCFG 0 7 AT TFICFG Set Query input transmission format configuration can be saved...

Страница 20: ...current device sleep time configuration Response DMCFG 0 or 2 30 AT DMCFG Value Parameter specification Value Sleep time unit S Can be set to 0 or 2 30 seconds Factory default parameter is 6 S Exampl...

Страница 21: ...efault 1 High 2 Medium 3 Low Example AT PWCFG 3 15 AT IOCFG Set Query IO port parameter configuration restart to take effect AT IOCFG Parameter specification Acquire the current device IO port paramet...

Страница 22: ...e data may be lost when the environment has large interference or multiple nodes transmit simultaneously 10 Notes 1 In the sleep mode the serial baud rate format is 115200 8N1 If users forget the curr...

Страница 23: ...embly Pb Free Assembly Solder Paste Solder paste Sn63 Pb37 Sn96 5 Ag3 Cu0 5 Preheat Temperature min Tsmin Minimum preheating temperature 100 150 Preheat temperature max Tsmax Maximum preheating temper...

Страница 24: ...eless radio wave so the performance will be poor when testing near ground Sea water has great ability in absorbing wireless radio wave so performance will be poor when testing near the sea The signal...

Страница 25: ...s under too high or too low temperature 13 Important statement EByte reserves the right of final interpretation and modification of all contents in this manual As the hardware and software of the prod...

Отзывы: