![Ebyte E70-433T14S Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/ebyte/e70-433t14s/e70-433t14s_user-manual_530539019.webp)
Chengdu Ebyte Electronic Technology Co,;Ltd
E70-433T14S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
18
00H~1FH, 425~450.5MHz
,(
Default
)
04H
(
433M
)
5
OPTION
7
Fixed transmission (similar to MODBUS
)
When it is 1, the first three bytes of each user data
frame can be used as high/low address and channel.
The module changes its address and channel when
transmitting. And it will revert to original setting
after the process is completed.
It is transparent transmission under continuous
mode.
0
Transparent transmission mode (Default
)
1
Fixed transmission mode
6
5
4
wireless wake-up time
This parameter is only valid for mode 4, 6.
For mode 6, the wake-up time will affect the WOR
cycle of the module, and affect the power
consumption.
For mode 4, the wake-up time decides the number
of wake-up code before transmission so as to
ensure the wake up the module in mode 6.
Generally, mode 4 and 6 shall be used jointly and
the wake-up time on both modules shall be the
same.
0
0
0
500ms
0
0
1
1000ms(Default)
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
3
FEC switch
After turn off FEC, the actual data transmission rate
increases while anti-interference ability decreases.
Also, the transmission distance is relatively short.
Both communication parties must keep on the same
pages about turn-on or turn-off FEC.
0
Turn off FEC
1
Turn on FEC (Default)
)
2
IO drive mode
This bit is used to the internal pull-up resistor. It
also increases the level’s adaptability in case of
open drain. But in some cases, it may need external
pull-up resistor.
0
TXD and AUX push-pull outputs, RXD
pull-up inputs
1
TXD
、
AUX open-collector outputs, RXD
open-collector inputs
1
0
transmission power (approximation)
The external power must ensure that the ability of
current output is more than 80mA and the power
supply ripple is within 100mV.
Low power transmission is not recommended due
to its low power supply efficiency.
0
0
14dBm (Default)
0
1
10dBm
1
0
7dBm
1
1
4dBm
For example: The meaning of No.3 "SPED" byte
:
The binary bit of the byte
7
6
5
4
3
2
1
0
The specific value
(configured by user)
0
0
0
1
1
0
1
0
Meaning
UART parity bit 8N1
UART
baud rate
is 9600
Air data rate is 2.4k
Corresponding hexadecimal
1
A