Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2020
Chengdu Ebyte Electronic Technology Co.,Ltd.
30
3
SPED
7
6
Serial port check digit
The serial port mode of the communication side can
be different.
0
0
8N1 (default).
0
1
8O1
1
0
8E1
1
1
8N1 (equivalent 00).
5
4
3
TTL serial port baud rate (bps).
The baud rate of the two sides of the communication
can be different;
The serial port baud rate has nothing to do with
wireless parameters and does not affect the wireless
transceiver characteristics.
0
0
0
The serial port baud rate is 1200
0
0
1
The serial port baud rate is 2400
0
1
0
The serial port baud rate is 4800
0
1
1
The serial port baud rate is 9600
(default).
1
0
0
The serial port baud rate is 19200
1
0
1
The serial port baud rate is 38400
1
1
0
The serial port baud rate is 57600
1
1
1
The serial port baud rate is 115200
2
1
0
Wireless air rate (bps).
The lower the air speed, the farther the distance, the
stronger the anti-interference performance, and the
longer the transmission time;
Both communicating parties must have the same
over-the-air wireless transmission rate.
0
0
0
The air speed is 2.5k (default).
0
0
1
The air rate is 5k
0
1
0
The air rate is 12k
0
1
1
The air rate is 28k
1
0
0
The air rate is 64k
1
0
1
The air speed is 168k
1
1
0
The air speed is 168k
1
1
1
The air speed is 168k
4
CHAN
7
6
5
Package
length
setting
(subcontracting mode only)
In continuous transmission mode (M2
, M1
, M0 =
001), this parameter is invalid.
0
0
0
16 bytes
0
0
1
32 bytes
0
1
0
64 bytes (default).
0
1
1
128 bytes
1
0
0
256 bytes
1
0
1
512 bytes
1
1
0
1024 bytes
1
1
1
2048 bytes
Communication channel
DEFAULT 04H (433MHZ).
00H~1FH, corresponding to 431~446.5MHz
5
OPTION
7
FIXED-POINT
TRANSMIT
ENABLE
BIT
( MODBUS-LIKE).
is 1
, the first
3
bytes
of each user data frame
serve as high, low, channel; When transmitting, the
module changes its own address and channel, and
after completion, it restores the original settings; The
continuous
transmission
mode is transparent
0
Transparent transmission (default)
1
Fixed-point transmission