background image

Chengdu Ebyte Electronic Technology Co,;Ltd

E62-DTU (433D30)user manual

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co,;Ltd

9

5.3.

Frequency range and channels

Model

Default frequency

Frequency range

Channel

spacing

Channels

Hz

Hz

Hz

E62-DTU (433D30)

433

425 ~ 450.5

0.1

Full-duplex

Note: In the same area when multiple data transceivers are communicating one to one at the same time, it is

recommended to set the channel spacing between each group of data transceivers at 2MHz or more.

5.4.

Transmit power level

Model

125mW

250mW

500mW

1W

E62-DTU (433D30)

Note: The lower the transmit power, the closer the transmission distance, but the working current won’t be declined in

exact proportion, it is recommended to use the maximum transmit power.

5.5.

Current parameters

Model

Transmitting current mA

Standby current mA

12V

24V

12V

24V

E62-DTU (433D30)

297

163

40

29

Note: It is recommended to retain more than 50% of the current margin when selecting the power supply, which will

help the data transceiver to work steadily for a long time.

5.6.

Transceiver Length and Sub-packing Mode

Model

Buffer

Sub-package

E62-DTU (433D30)

2048Byte

Large buffer

Note:

1. When the receiving data is more than a single packet capacity, the beyond part will be automatically assigned

to the second transmission until it is completed;

Содержание E62-DTU (433D30)

Страница 1: ...E62 DTU 433D30 ...

Страница 2: ...7 4 2 RS232 Interface definition 7 4 3 RS485 Interface definition 7 5 Technical indicators 8 5 1 Model specifications 8 5 2 General specification parameters 8 5 3 Frequency range and channels 9 5 4 Transmit power level 9 5 5 Current parameters 9 5 6 Transceiver Length and Sub packing Mode 9 6 Operating mode 10 7 Connection diagram when programming 11 7 1 Diagrammatic drawing 11 7 2 Parameter setti...

Страница 3: ...end and receive the packet size module can keep low latency high response at the same time to ensure that the data is transmitted to the other party as soon as possible E62 DTU 433D30 strictly abides by domestic and foreign design specifications such as FCC CE and CCC and meets various radio frequency related certifications and export requirements 1 2 Features All core components are originally im...

Страница 4: ...s to mount antenna then battery making sure the dial switch is on its right status User gets on the power by choosing either VCC GND or power adapter 2 Using USB RS232 converter or USB RS 485 converter or other way to link computer and DTU 3 Firing up two XCOMs choosing Baud rate 9600bps 8N1 the setting which serial port transmission can be achieved ...

Страница 5: ...n the mode switch first before link DTU with computer if the user want to modify parameters Firing up E62 DTU 数传电台配置软件 E62 DTU parameter configuration application to modify related parameters The mode switch must be reopened to achieve transmission after the configuration Mode 0 Default Mode 1 Parameter setting 3 Installation Specifications 3 1 Structure ...

Страница 6: ...power interface Standard RS 485 interface and pressure line power interface 3 PWR LED Power LED Red lit when the power is on 4 TXD LED Transmit LED Yellow blinks when sending data 5 RXD LED Receive LED Yellow blinks when receiving data 6 DC power interface Power interface In line round hole outer diameter 5 5mm diameter 2 5mm 7 DIP switch DIP switch Controlled by working mode 8 Antenna interface S...

Страница 7: ...Chengdu Ebyte Electronic Technology Co Ltd E62 DTU 433D30 user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 6 3 2 Dimension Unit mm ...

Страница 8: ...rminal power supply only choose any one of the power supply is OK E62 DTU 433D30 can use 10 28V DC power supply but it is recommended to use 12V or 24V DC power supply 4 2 RS232 Interface definition The E62 DTU 433D30 can be connected to the device via RS 232 using the standard DB 9 interface 4 3 RS485 Interface definition E62 DTU 433D30 can connect the 485_A terminal and 485_B terminal with the d...

Страница 9: ... Model specifications Model Frequency Transmit power Distance Specifications Application Hz W km E62 DTU 433D30 433 1 3 Full duplex automatic frequency hopping spread spectrum Suitable for open environment with few obstacles Note Test condition in clear and open air without shelters 12V 2A power supply 5dBi gain sucker antenna over 2 meters height from the ground with the factory default parameter...

Страница 10: ...433D30 Note The lower the transmit power the closer the transmission distance but the working current won t be declined in exact proportion it is recommended to use the maximum transmit power 5 5 Current parameters Model Transmitting current mA Standby current mA 12V 24V 12V 24V E62 DTU 433D30 297 163 40 29 Note It is recommended to retain more than 50 of the current margin when selecting the powe...

Страница 11: ...de E62 DTU 433D30 has two operating modes if low power consumption is not required transmission mode mode 0 is recommended for transmission The factory default is transmission mode mode 0 Categories M1 M0 Description Mode 0 Transmission mode ON ON Serial port open wireless open transparent transmission full duplex operation Mode 1 Configuration mode ON OFF Serial port at fixed 9600bps baud rate wi...

Страница 12: ...ming 7 1 Diagrammatic drawing Mode M1 M0 Description Mode 1 Configuration mode ON OFF Serial port at fixed 9600bps baud rate wireless off configurable parameters Note 1 programming can only be carried on in a specific mode see above if fails please confirm the work mode 2 If there s no complicated programming opening the E62 DTU 数传电台配置软件 E62 DTU parameter configuration ...

Страница 13: ...Transmitting power In order to ensure the working efficiency it is recommended to use the maximum power If the transmitted power is reduced the communication distance will become shorter and the required current will be reduced FEC The lost or interfered data can be partially corrected by complex encoding which can improve the equivalent receiving sensitivity by about 3dBm Turning off this functio...

Страница 14: ...ission station works Each channel corresponds to its different working frequency In theory different frequency channels cannot communicate with each other Frequency hopping channel number The more channels are hopped between when the radio is working and the more the number of hopping channels the better the anti interference performance 8 Connection diagram in test and application 9 E62 DTU serie...

Страница 15: ...l monitoring and other industrial automation system as shown below 11 Note 1 Please keep the warranty card of the equipment which includes the factory number and important technical parameters and is important for user s future maintenance and new equipment 2 Transceiver during the warranty period if the quality of the product itself rather than man made damage or lightning and other natural disas...

Страница 16: ...ed easily the distance from the antenna is better than 2 meters so as to avoid harm please do not touch the antenna when transmitting 9 Wireless data transceiver has different communication distance in different environments communication distance is influenced by temperature humidity obstacle density obstacle volume and electromagnetic environment in order to ensure stable communication it is rec...

Отзывы: