background image

Chengdu Ebyte Electronic Technology Co.,Ltd

E30-900M30S User Manual

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.

5

2 Specification and Parameter

2.1 Limit Parameter

Main parameter

Performance

Remark

Min

Max

Power supply

V

1.8

5.5

Voltage over 3.6V will cause permanent damage to
module

Blocking power

dBm

-

10

Chances of burn is slim when modules are used in
short distance

Operating temperature

-40

+85

Industrial grade

2.2 Operating Parameter

Main parameter

Performance

Remark

Min

Typical

Max

Operating voltage

V

0

5.0

5.5

3.3 V ensures output power

Communication level

V

-

3.3

-

For 5V TTL, it may be at risk of burning down

Operating temperature

-40

-

+85

Industrial grade

Operating frequency

MHz

855

-

925

-

Power

Consump

- tion

TX current

mA

550

650

700

Instant power consumption

RX current

mA

-

22

-

-

Sleep current

μA

-

2

-

-

Max TX power

dBm

29

30

30.5

-

Receiving sensitivity

dBm

-120

-121

-122

Air data rate is1kbps

Main parameter

Description

Remark

Reference distance

5.6Km

Test condition

clear and open area, antenna gain: 5dBi

antenna height: 2.5m

air data rate: 1kbps

Modulation

GFSK

-

Communication Interface

SPI

Max. rate 10Mbps

Package

SMD

-

Interface method

Stamp Hole

-

Size

38.5*24mm

-

Antenna

IPEX/STAMP

50 ohm impedance

Содержание E30-900M30S

Страница 1: ...E30 900M30S SI4463 400MHz 1W SPI Wireless Module...

Страница 2: ...3 Application 4 2 Specification and parameter 5 2 1 Limit parameter 5 2 2 Operating parameter 5 3 Size and pin definition 6 4 Recommended circuit diagram 7 5 Hardwar design 6 FAQ 8 6 1 Communication r...

Страница 3: ...or other ways whether express or implied The test data obtained in the article are all obtained by the Ebyte laboratory and the actual results may vary slightly We hereby declared that all brand name...

Страница 4: ...widely used in various industries and has the characteristics of stable performance long transmission distance and strong ability of penetration and diffraction etc 1 2 Features The measured communic...

Страница 5: ...ax Operating voltage V 0 5 0 5 5 3 3 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial grade Operating frequency MHz...

Страница 6: ...6 IO_2 Output Configurable universal GPIO port see SI4463manual for details 7 IO_3 Output Configurable universal GPIO port see SI4463manual for details 8 IO_0 Output Configurable universal GPIO port...

Страница 7: ...diagram 5 Hardware design It is recommended to use a DC stabilized power supply The power supply ripple factor is as small as possible and the module needs to be reliably grounded Please pay attentio...

Страница 8: ...ion and shielding can be done If the communication line uses a 5V level a 1k 5 1k resistor must be connected in series not recommended there is still a risk of damage Try to stay away from some physic...

Страница 9: ...le the soldering personnel must work in accordance with the anti static operation specification This product is an electrostatic sensitive product If the module is not welded according to the specific...

Страница 10: ...Therefore we recommend some antennas for wireless modules with excellent performance and reasonable price 10 Package method for bulk order Model No Type Frequeny Hz Interface Gain dBi Hight mm Cable m...

Страница 11: ...Ltd 11 Revision history Version Date Description Issued by 1 0 2021 08 09 Content updated Linson About us Sales hotline 0086 4000 330 990 Tel 0086 28 61399028 Technical support support cdebyte com Web...

Отзывы: