Chengdu Ebyte Electronic Technology Co., Ltd.
E220P-400T22S User Manual
Copyright ©2012–2020,
Chengdu Ebyte Electronic Technology Co., Ltd.
13
it can be used as the broadcast and monitor
address, that is: the module will not perform
address filtering at this time
01H
Read/
Write
ADDL
ADDL
(
default 0
)
02H
Read/
Write
REG0
7
6
5
UART Serial Port Rate
(
bps
)
For the two modules that communicate with each
other, the serial port baud rate can be different,
and the verification method can also be different;
When continuously transmitting large data
packets, users need to consider the data
congestion caused by the same baud rate, and may
even be lost;
It is generally recommended that the baud rate of
the two communication parties be the same.
0
0
0
UART Rate is 1200
0
0
1
UART Rate is 2400
0
1
0
UART Rate is 4800
0
1
1
UART Rate is 9600
(
default
)
1
0
0
UART Rate is 19200
1
0
1
UART Rate is 38400
1
1
0
UART Rate is 57600
1
1
1
UART Rate is 115200
4
3
Serial Parity Bit
The serial port mode of the communication parties
can be different;
0
0
8N1
(
default
)
0
1
8O1
1
0
8E1
1
1
8N1
(
equal to 00
)
2
1
0
Air Data Rate
(
bps
)
The air rate of both parties must be the same;
The higher the air rate, the smaller the delay and
the shorter the transmission distance.
0
0
0
Air Data Rate 2.4k
0
0
1
Air Data Rate 2.4k
0
1
0
Air Data Rate 2.4k
(
default
)
0
1
1
Air Data Rate 4.8k
1
0
0
Air Data Rate 9.6k
1
0
1
Air Data Rate 19.2k
1
1
0
Air Data Rate 38.4k
1
1
1
Air Data Rate 62.5k
03H
Read/
Write
REG1
7
6
Sub-Packet Setting
The data sent by the user is less than the
sub-packet length, and the serial port output of the
receiving end appears as an uninterrupted
continuous output;
The data sent by the user is larger than the packet
length, and the serial port of the receiving end will
be output in packets.
0
0
200 bytes
(
default
)
0
1
128 bytes
1
0
64 bytes
1
1
32 bytes
5
RSSI Ambient noise enable
After enabling, you can send commands C0 C1
C2 C3 in transmission mode or WOR sending
mode to read registers;
Register 0x00: Current environmental noise RSSI;
Register 0X01: RSSI when receiving data last
time
(The current channel noise is: dBm = -
(
256 -
RSSI
)
);
Instruction format: C0 C1 C2 C3+start
read length;
Return: C1 + a read read valid
value; for example: send C0 C1 C2 C3 00 01
Return C1 00 01 RSSI
(address can only start
from 00)
0
Disable
(
Default
)
1
Enable
4
3
2
Reserve