Chengdu Ebyte Electronic Technology Co., Ltd.
E220-900T30S User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
16
The maximum stay time of LBT is 2 seconds, and
it will be issued forcibly when it reaches 2
seconds.
3
Reserve
2
1
0
WOR Cycle
Only valid for mode 1;
Cycle T= (1+WOR)*500ms, the maximum is
4000ms, the minimum is 500ms;
The longer the WOR monitoring interval period,
the lower the average power consumption, but the
greater the data delay;
Both sender and receiver must agree (very
important)
0
0
0
500ms
0
0
1
1000ms
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
06H
Write
CRYPT
_H
Key high byte
(
default 0
)
Write only, read returns 0;
Used for encryption to avoid interception of
wireless data in the air by similar modules;
The module will use these two bytes as a
calculation factor to transform and encrypt the air
wireless signal.
07H
Write
CRYPT
_L
Key low byte
(
default 0
)
7.3 Factory Default Parameter
Model
Factory default parameter
:
C0 00 00 62 00 17
Model No.
Frequency
Address
Channel
Air Rate
Baud Rate
Serial Format
Power
E220-900T30S
873.125MHz
0x0000
0x17
2.4kbps
9600
8N1
30dbm