2. Specification and Parameter
2.1 Limit Parameter
Table 2-1 Limit parameter table
Main Parameter
Performance
Remark
Min.
Min.
Power Supply
(
V
)
-
5.5
Exceeding the maximum value may burn the
module permanently
Blocking Power
(
dBm
)
-
10
-
Operating Temperature
(℃)
-40
+85
Industrial grade
2.2 Operating Parameter
Table 2-2 Working parameter table
Main Parameter
Performance
Remark
Min.
Typ.
Max.
Operating voltage
(
V
)
3.0
5
5.5
≥5.0 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be burning down
Operating temperature
(
℃
)
-40
-
+85
Industrial design
Operating frequency
(
MHz
)
220.125
-
230.125
Support ISM band
Power
consumption
TX current
(mA)
-
620
-
Instant power consumption @30dBm
RX current
(mA)
-
17.2
-
5V Voltage
Sleep current
(
μA
)
-
5
-
software shutdown
Max Tx power
(
dBm
)
29
30
30
-
Receiving sensitivity
(
dBm
)
-146
-147
-148
Air data rate 2.4kbps
Air data rate
(
bps
)
2.4k
2.4k
62.5k
To control via user’s program
Distance for reference
10km
Test condition
:
clear and open area, antenna
gain: 5dBi
,
antenna height: 2.5m
,
air data rate:
2.4kbps
TX length
200 Byte
Can be configured via command as
32/64/128/200 bytes per packet to transmit
Buffer
400 Byte
-
Modulation
LoRa
New generation LoRa modulation technology
Communication interface
UART Serial Port
TTL Level
Package
DIP
-
Size
24*43mm
-
Antenna
SMA-K