(4) For example, when the terminal is the receiving end, enter the configuration mode, change the network group
number to "4", and then write the parameter. At this time, because the network group number is not "5", the coordinator
multicast data cannot be received.
7.3.3 Broadcast test
(1) For example, the coordinator broadcasts, click "Enter configuration mode", enter the fixed network, select the
broadcast mode, and then write the parameters. A message box prompts "Write parameters successfully".
(2) Enter the transmission mode, the message box prompts "Successfully entered the transmission mode", and then
broadcast data communication. At this time, all nodes in the network will receive data, including the sender node.